Switch Emergency Stop Surface 3Ph Triple Pole IP65 63A 400V 50/60Hz

Switch Emergency Stop Surface 3Ph Triple Pole IP65 63A 400V 50/60Hz

£118.28 Incl. VAT

Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: P3, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, Information about equipment supplied: Auxiliary contact or neutral conductor fitted by user., 3 pole, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65, Design: surface mounting, Motor rating AC-23A, 50 – 60 Hz 400 V: P = 30 kW, Rated uninterrupted current: Iu = 63 A, Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3 · · · Colour: Red (Rotary Handle), Yellow (Locking Collar) · · Current Rating: 63A · · Height: 240mm · · Width: 160mm · · Depth: 95mm · · Frequency: 50 – 60Hz

1 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: P3-63/I4/SVB Categories: , , Brand: Part Number: 2500094447

Description

Technical Specifications  Technical Specifications Switch disconnector / isolator Degree of protection (NEMA) 12 Colour control element Red Device construction Complete device in housing Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as normally closed contact 0 Number of poles 3 Rated operation power at AC-3, 400 V 30 kW Type of electrical connection of main circuit Screw connection Type of control element Door coupling rotary drive Degree of protection (IP), front side IP65 Conditioned rated short-circuit current Iq 4 kA Number of auxiliary contacts as change-over contact 0 Rated permanent current Iu 63 A Rated short-time withstand current lcw 1.26 kA Number of switches 1 Max. rated operation voltage Ue AC 690 V Rated operation power at AC-23, 400 V 30 kW Rated permanent current at AC-21, 400 V 63 A Rated operating voltage 690 – 690 V Switching power at 400 V 30 kW Rated permanent current at AC-23, 400 V 63 A Version as emergency stop installation Yes Motor drive integrated No Version as main switch Yes Version as safety switch No Version as maintenance-/service switch Yes Interlockable Yes Suitable for front mounting 4-hole No Suitable for front mounting centre No Suitable for distribution board installation No Version as reversing switch No Suitable for intermediate mounting No Motor drive optional No Voltage release optional No · Technical Data Sheet – Click to Download