Schneider RCCB Four Pole Class AC 40A 30mA 72 x 91 x 73.5mm

Schneider RCCB Four Pole Class AC 40A 30mA 72 x 91 x 73.5mm

£224.11 Incl. VAT

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with In rated current of 40A, AC type protection class and a 30mA earth leakage sensitivity. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C. · · · This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). · · It is a 4P circuit breaker with In rated current of 40A, AC type protection class and a 30mA earth leakage sensitivity. · · This product protects against electrical shock by direct or indirect contact and fire hazards. · · It performs the function of disconnection of electrical circuits in case of earth fault. · · Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. · · This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance · · This product is compliant with EN/IEC 61008-1 standard. · · The (Im/I?m) rated breaking and making short circuit capacity is 1500A. The (Inc/I?c) conditional rated short circuit current is 10kA. · · The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. · · The Ue operational voltage is 380VAC to 415VAC.

4 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9R41440 Categories: , , Brand: Part Number: 2500584135

Description

Technical Specifications  Technical Specifications Residual current circuit breaker (RCCB) Number of poles 4 Rated current 40 A Recess depth 73.5 mm Surge current capacity 0.25 kA Rated impulse-withstand voltage (Uimp) 6 kV Rated insulation voltage Ui 500 V Rated fault current 30 A Short-circuit breaking capacity (Icw) 10 kA Width in number of modular spacings 4 Rated voltage 415 V Ambient temperature during operating -5 – 60 °C Connectable conductor cross section multi-wired 1 – 25 mm² Connectable conductor cross section solid-core 1 – 35 mm² Pollution degree 3 Selective protection No Short-time delayed tripping No With interlocking device No Additional equipment possible Yes · Technical Data Sheet – Click to Download