Schneider Electric RCBO Ic60H Single Pole + Neutral Class A Type C 10A 30mA 10kA
£131.17 Incl. VAT
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 10A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with BS EN 61009-1 and IEC 61009-1 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is white (RAL9003). The dimensions are (W) 18mm x (H) 110mm x (D) 77.5mm. The weight is 205g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C. · · · Green Premium Product · · C Curve · · DIN Rail Mounted · · ON/OFF locking facilities · · Standards – BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 and AS/NZS 61009.1 · · Euro-slot packaging · · Complete with lock nut and washer · · This product is compliant with BS EN 61009-1 and IEC 61009-1 standard. · · It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ue operational voltage is 240VAC.
✓ In stock – Delivery in 1–2 days
Description
Technical Specifications Technical Specifications Earth leakage circuit breaker/RCBO Tripping characteristic (type/curve) C Mounting method DIN rail Rated current 10 A Recess depth 45 mm Rated impulse-withstand voltage (Uimp) 4 kV Rated voltage 240 V Pollution degree 3 Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA Over voltage category 4 Surge current capacity 0.25 kA Width in number of modular spacings 1 Number of poles (total) 2 Current limiting class 3 Number of protected poles 1 Rated insulation voltage Ui 400 V Rated fault current 0.03 A Connectable conductor cross section solid-core 1 – 25 mm² Connectable conductor cross section multi-wired 1 – 16 mm² Ambient temperature during operating -15 – 60 °C Concurrently switching N-neutral Yes Anti-nuisance tripping version No With interlocking device No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2200034






