Schneider MCB Acti9 iC60H Double Pole Type C 10A 30kA
£74.89 Incl. VAT
This Acti9 iC60H is a multistandard low voltage miniature circuit breaker (MCB) with double tunnel terminals. It is a 2P circuit breaker with 2 protected poles, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 30kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 10000A at 415VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 78.5mm. The weight is 0.25kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C. · · · Green Premium Product · · Thermal-magnetic trip unit technology · · C Curve · · Clip-on DIN rail mounting mode · · 20000 cycle mechanical durability · · 10000 cycle electrical durability · · Padlockable · · Its fast closing mechanism independent of manual operation improves its service life. · · It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ui rated insulation voltage is 500VAC.
39 available – delivery in 1–2 days
Description
Technical Specifications Technical Specifications Miniature circuit breaker (MCB) Rated current 10 A Recess depth 44.5 mm Rated voltage 415 V Tripping characteristic (type/curve) C Number of protected poles 2 Rated insulation voltage Ui 500 V Current limiting class 3 Rated short-circuit breaking capacity Icn EN 60898 at 400 V 10 kA Number of poles (total) 2 Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 15 kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 30 kA Over voltage category 4 Width in number of modular spacings 2 Rated impulse-withstand voltage (Uimp) 6 kV Pollution degree 3 Frequency 50 – 60 Hz Connectable conductor cross section solid-core 1 – 25 mm² Connectable conductor cross section multi-wired 1 – 16 mm² Ambient temperature during operating 35 – 70 °C Suitable for flush-mounted installation No Concurrently switching N-neutral No Additional equipment possible Yes · Technical Data Sheet – Click to Download