Schneider RCCB Four Pole Class AC 63A 300mA
£224.11 Incl. VAT
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with In rated current of 63A, AC type protection class and a 300mA earth leakage sensitivity. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C. · · · 1 Group of 11 Digital Channels · · Upto 11 Wired Devices · · Web Server BMS controller compatible · · Simple to choose with meaningful part numbers · · Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections · · This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance · · This product is compliant with EN/IEC 61008-1 standard. · · The (Im/I?m) rated breaking and making short circuit capacity is 1500A. The (Inc/I?c) conditional rated short circuit current is 10kA. · · The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. · · The Ue operational voltage is 380VAC to 415VAC.
6 available – delivery in 1–2 days
Description
Technical Specifications Technical Specifications Residual current circuit breaker (RCCB) Pollution degree 3 Rated impulse-withstand voltage (Uimp) 6 kV Recess depth 73.5 mm Rated voltage 415 V Number of poles 4 Rated current 63 A Width in number of modular spacings 4 Surge current capacity 0.25 kA Short-circuit breaking capacity (Icw) 10 kA Rated fault current 300 A Rated insulation voltage Ui 500 V Connectable conductor cross section solid-core 1 – 35 mm² Connectable conductor cross section multi-wired 1 – 25 mm² Ambient temperature during operating -5 – 60 °C Selective protection No Short-time delayed tripping No Additional equipment possible Yes With interlocking device No · Technical Data Sheet – Click to Download