Iprd40 Modular Surge Arrester 3 Pole + Neutral 350V

Iprd40 Modular Surge Arrester 3 Pole + Neutral 350V

£819.50 Incl. VAT

This Acti9 iPRD40 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. Modular design (cartridge type) DIN rail mounted The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Imax rated discharge current is 40kA. The In nominal discharge current is 15kA. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard. · · · This Acti9 iPRD40 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. · · The Up voltage protection level in DM differential mode (between phase and neutral) is below or equal to 1.6kV. · · It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. · · The associated circuit breaker Isc breaking capacity can go up to 50kA. · · This Acti 9 iPRD40 is compatible with TT and TN-S earthing system. · · The Imax rated discharge current is 40kA. The In nominal discharge current is 15kA. · · The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. · · The Uc maximum continuous operating voltage in CM common mode (between neutral and earth) is 260VAC. · · The Up voltage protection level in DM differential mode (between phase and neutral) is below or equal to 1.6kV. · · The Up Voltage protection level in CM common mode and in DM differential mode is below or equal to 1.4kV.

7 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9L40600 Categories: , Brand: Part Number: 2500866980

Description

Technical Specifications  Technical Specifications Surge protection device for power supply systems Nominal voltage AC 350 V Nominal voltage DC – V Voltage protection level N-PE 1.4 kV Max. continuous voltage DC – V Max. PV-voltage – V Max. conductor cross section solid (solid, stranded) 35 mm² Voltage protection level L-N 1.4 kV Max. conductor cross section flexible (fine-strand) 35 mm² Max. voltage (Uc) 350 V System configuration TN-C-S No System configuration other No Number of conductors (without earthing) 3 Voltage protection level 1.4 kV Nominal discharge surge current 8/20 µs (In) 15 kA Short-circuit breaking capacity (Isccr) – kA Max. discharge surge current (8/20) 40 kA System configuration TN-S Yes System configuration TT Yes System configuration TN No System configuration TN-C No System configuration DC No System configuration IT No With remote signalling contact No Type / Test class 2 Yes Integrated backup fuse No · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2224955