Schneider Acti 9 iID, RCCB, 2p, 100A, 300mA, type AC
£191.27 Incl. VAT
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with 100A In rated current, a sensitivity of 300mA with a AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The mechanical endurance is going up to 20000 cycles and electrical endurance going up to 10000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C. · · · This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). · · It is a 2P circuit breaker with 100A In rated current, a sensitivity of 300mA with a AC type protection class. · · This product protects against electrical shock by indirect contact and fire hazards. · · It performs the function of disconnection of electrical circuits in case of earth fault. · · Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face.
5 available – delivery in 1–2 days
Description
Technical Specifications Technical Specifications Residual current circuit breaker (RCCB) Width in number of modular spacings 2.00 Rated voltage 230.00 V Number of poles 2.00 Recess depth 73.50 mm Surge current capacity 0.25 kA Rated current 100.00 A Short-circuit breaking capacity (Icw) 1.50 kA Connectable conductor cross section multi-wired 1.00 – 25.00 mm² Connectable conductor cross section solid-core 1.00 – 35.00 mm² Rated fault current 300.00 A Rated insulation voltage Ui 500.00 V Rated impulse-withstand voltage (Uimp) 6.00 kV Pollution degree 3.00 Selective protection No Ambient temperature during operating 5.00 – 60.00 °C Short-time delayed tripping No With interlocking device Yes Additional equipment possible Yes