Photo-electric sensor, XUB, receiver, Sn 15m, 12..24VDC, M12
£77.74 Incl. VAT
Photo-electric sensor, XUB, receiver, Sn 15m, 12..24VDC, M12. range of product: OsiSense XU – series name: general purpose single mode – electronic sensor type: photo-electric sensor receiver – sensor name: XUB – detection system: thru beam – material: plastic – line of sight type: axial – type of output signal: discrete – wiring technique: 3-wire – product specific application: -. · · · This design 18 single mode (thru-beam system) photo-electric receiver has a PBT case. · · It has a supply voltage of 12V to 24V DC. · · This mono-mode cylindrical photoelectric receiver has a plastic body, is mountable directly on a surface or bracket, thanks to its outer thread and twin nuts. · · It has VALOX® PBT high strength case ideal for high temperature environments and PMMA scratch-resistant lens for maximum sensor durability. · · 1 LED display allows to identify status of the sensor.
Out of stock
Description
Technical Specifications Technical Specifications Through beam photoelectric sensor Housing material Plastic Laser protection class None Material of optical surface Plastic Explosion safety category for dust None Scope of delivery of the one-way system Receiver Explosion safety category for gas None Construction type housing Cylinder, screw-thread Type of light Infrared light Sensing mode Dark switching Type of electric connection Connector M12 Operation agent-safety class Safety class 0 Diameter sensor 18 mm Max. switching distance 20000 mm Degree of protection (IP rating) IP65 Voltage type AC/DC Type of safety acc. IEC 61496-1 1 Type of switching output PNP/PNP Type of switch function Normally open contact (NO) Reaction time 1 ms Rated switching distance 15000 mm Length of sensor 60 mm AWG-number – Wavelength of the sensor – nm Switching frequency 500 Hz Number of protected semiconductor outputs 1 Light dot – mm² Width sensor – mm Max. output current at protected output 100 mA Transmission range of the safety field – m Switching voltage of OSSD at state “high” – V Opening angle 0 ° Number of protected contact energized outputs 0 Number of semiconductor outputs with signalling function 1 Height of sensor – mm Min. reflector distance 5000 mm Number of contact energized outputs with signalling function 0 Maximum output current 100 mA Ambient temperature -25 – 55 °C Rated control supply voltage at AC 50 Hz – V Rated control supply voltage at AC 60 Hz – V Rated control supply voltage at DC 12 – 24 V With restart blockage No Analogue output 0 mA … 20 mA No Analogue output 4 mA … 20 mA No Analogue output 0 V … 10 V No With communication interface INTERBUS No With communication interface RS-422 No With communication interface SSD No With communication interface SSI No With communication interface PROFIBUS No With communication interface CANOpen No With communication interface AS-Interface No With communication interface Ethernet No With communication interface DeviceNet No With communication interface RS-485 No With communication interface RS-232 No Reflector included No Analogue output -10 V … +10 V No With communication interface analogue No With other analogue output No With monitoring function downstream switching devices No Pre failure notice No With time function No Suitable for safety functions No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2188162






