TeSys 0.35-1.4A Advanced Control Unit 110-240V DC/AC

TeSys 0.35-1.4A Advanced Control Unit 110-240V DC/AC

£109.79 Incl. VAT

TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 0.25kW@400V. It provides full protection to motors with a rated current Ir 0.35-1.4A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). It provides a thermal overload alarm to be used locally using a LUFDA module or remotely using a LULC module, and a test push button for overload simulation. To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). · · · TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 0.25kW@400V. · · It provides full protection to motors with a rated current Ir 0.35-1.4A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). · · It provides a thermal overload alarm to be used locally using a LUFDA module or remotely using a LULC module, and a test push button for overload simulation. · · Control circuit voltage limits: 88 – 242V DC/88 – 264V AC · · To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). · · Vibration resistance: 2-4gn (open/closed) · · Fire resistance: 650°C · · IP20/40 Degree of protection · · Ambient temperature: -25°C to 70°C · · RoHS compliant

Out of stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: LUCB1XFU Categories: , , Brand: Part Number: 2500184797

Description

Technical Specifications  Technical Specifications Trip block for power circuit-breaker Rated permanent current Iu 1.40 A Initial value of the undelayed short-circuit release – setting range 18.00 A End value adjustment range undelayed short-circuit release 18.00 A Number of poles 3.00 Overload release current setting 0.35 – 1.40 A Rated control supply voltage at AC 60 Hz 110.00 – 240.00 V Rated control supply voltage at DC 110.00 – 220.00 V Rated control supply voltage at AC 50 Hz 110.00 – 240.00 V With ground fault protection function Yes · Technical Data Sheet – Click to Download