Schneider Electric Voltage interface module, TeSys island

Schneider Electric Voltage interface module, TeSys island

£166.27 Incl. VAT

TeSys island voltage interface module, 100-690V / 47-63Hz. Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence. Voltage measurement range 100-690 V +/- 5 %, phase frequency measurement range 47-63 Hz +/- 1 Hz in single phase or 3-phase systems. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh). · · · TeSys island voltage interface module, 100-690V / 47-63Hz. · · Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. · · It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence. · · Voltage measurement range 100-690 V +/- 5 %, phase frequency measurement range 47-63 Hz +/- 1 Hz in single phase or 3-phase systems.

Typically available in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: TPRVM001 Categories: , Brand: Product Code: 2501393219

Description

Technical Specifications  Technical Specifications Fieldbus, decentr. periphery – analogue I/O module Width 25 mm Height 118 mm Depth 114 mm Number of HW-interfaces RS-232 0 Number of HW-interfaces RS-422 0 Number of HW-interfaces industrial Ethernet 0 Number of analogue outputs 0 Number of analogue inputs 3 Number of HW-interfaces RS-485 0 Number of HW-interfaces parallel 0 Number of HW-interfaces serial TTY 0 Number of HW-interfaces Wireless 0 Number of HW-interfaces PROFINET 0 Number of HW-interfaces other 2 Resolution of the analogue inputs 13 Bit Number of HW-interfaces USB 0 Resolution of the analogue outputs – Bit Supply voltage AC 50 Hz – – – V Supply voltage AC 60 Hz – – – V Supply voltage DC 20.4 – 28.8 V Suitable for safety functions No Supporting protocol for TCP/IP No Supporting protocol for ASI No Supporting protocol for LON No Supporting protocol for PROFIBUS No Supporting protocol for INTERBUS No Supporting protocol for CAN No Supporting protocol for KNX No Supporting protocol for MODBUS No Supporting protocol for SUCONET No Supporting protocol for DeviceNet No Supporting protocol for Data-Highway No Input, resistance thermometer No Input, resistor No Input, current No Input, voltage Yes Radio standard UMTS No Radio standard GSM No Radio standard GPRS No Supporting protocol for SafetyBUS p No Supporting protocol for PROFIsafe No Supporting protocol for PROFINET CBA No Supporting protocol for PROFINET IO No IO link master No Radio standard WLAN 802.11 No Radio standard Bluetooth No Supporting protocol for INTERBUS-Safety No Supporting protocol for other bus systems Yes Analogue inputs configurable No Input, thermocouple No Supporting protocol for SERCOS No Input signal, configurable No Analogue outputs configurable No System accessory Yes Supporting protocol for EtherNet/IP No Supporting protocol for DeviceNet Safety No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for Foundation Fieldbus No Rail mounting possible Yes Appendant operation agent (Ex ia) No Output signal configurable No Output, voltage No Output, current No Appendant operation agent (Ex ib) No Front built-in possible No Wall mounting/direct mounting No Rack-assembly possible No Fieldbus connection over separate bus coupler possible Yes · Technical Data Sheet – Click to Download