Schneider Electric Direct online SIL starter, TeSys island, 30A AC-1, 25A AC-3, 11kW / 15hp
£89.00 Incl. VAT
TeSys island direct SIL starter, 3 poles, 25A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 25A and motors up to 11kW@400V / 15hp@480V. In association with a TPRSM001 module and an external safety device, it can be used for safety related systems conforming to IEC 61508. It provides motor protection functions including thermal overload (setting 0.5-25A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh). · · · TeSys island direct SIL starter, 3 poles, 25A/690V. · · Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 25A and motors up to 11kW@400V / 15hp@480V. · · In association with a TPRSM001 module and an external safety device, it can be used for safety related systems conforming to IEC 61508. · · It provides motor protection functions including thermal overload (setting 0.5-25A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. · · Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module.
Out of Stock
Description
Technical Specifications Technical Specifications Fieldbus, decentr. periphery – power module, motor switch Width 45.00 mm Number of HW-interfaces RS-232 0.00 Number of HW-interfaces industrial Ethernet 0.00 Number of inputs 1.00 Number of HW-interfaces other 2.00 Number of HW-interfaces USB 0.00 Number of motor outlets 1.00 Number of HW-interfaces Wireless 0.00 Number of HW-interfaces PROFINET 0.00 Number of HW-interfaces RS-485 0.00 Number of HW-interfaces RS-422 0.00 Number of HW-interfaces parallel 0.00 Number of HW-interfaces serial TTY 0.00 Height 121.00 mm Depth 115.00 mm Rated operation current of the motor 0.50 – 25.00 A Supply voltage AC 50 Hz – – – V Supply voltage AC 60 Hz – – – V Supply voltage DC 20.40 – 28.80 V Permitted voltage at output 0.00 – 690.00 V Permitted voltage at input 0.00 – 690.00 V Short-circuit protection, outputs available No Supporting protocol for LON No Suitable for safety functions Yes Supporting protocol for ASI No Supporting protocol for TCP/IP No Supporting protocol for PROFIBUS No Supporting protocol for MODBUS No Supporting protocol for Data-Highway No With optical interface No Supporting protocol for CAN No Supporting protocol for INTERBUS No Supporting protocol for KNX No Supporting protocol for DeviceNet No Supporting protocol for SUCONET No Supporting protocol for other bus systems Yes Supporting protocol for SERCOS No Supporting protocol for INTERBUS-Safety No Radio standard Bluetooth No IO link master No Radio standard WLAN 802.11 No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for DeviceNet Safety No Supporting protocol for EtherNet/IP No Supporting protocol for PROFINET IO No Supporting protocol for Foundation Fieldbus No System accessory Yes With brake output No With motor current parameter setting No With thermal motor protection Yes Supporting protocol for PROFINET CBA No Supporting protocol for PROFIsafe No Supporting protocol for SafetyBUS p No Radio standard GPRS No Radio standard GSM No Radio standard UMTS No Rail mounting possible Yes Fieldbus connection over separate bus coupler possible Yes Appendant operation agent (Ex ia) No Appendant operation agent (Ex ib) No Front built-in possible No Rack-assembly possible No Wall mounting/direct mounting No · Technical Data Sheet – Click to Download