Schneider Multi9 - C60N - MCB - 2P - 20 A - C Curve - 415 V - 10 kA

Schneider Multi9 – C60N – MCB – 2P – 20 A – C Curve – 415 V – 10 kA

£68.35 Incl. VAT

Multi9™ is a range of DIN rail modular devices, a solution offering great performance. Multi9 range is a Schneider Electric global offer dedicated to equipment manufacturers (OEMs), meeting the major standards for industry applications. Designed to meet your needs for most types of machines, offering a wide range of modular devices it provides protection, signalling functions and accessories. · · · This Multi9 C60N is a low voltage miniature circuit breaker (MCB). · · It is a 2P circuit breaker with 2 protected poles, 20A rated current and C tripping curve. · · The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard. · · This product complies with industrial standard EN/IEC 60947-2. · · It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. · · This product protects from short circuit, earth leakage and overload. · · Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. · · This product is dedicated for original equipment manufacturers (OEM) and control panel builders. · · It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC.

2 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: M9F11220 Categories: , , Brand: Part Number: 2501537518

Description

Technical Specifications  Technical Specifications Miniature circuit breaker (MCB) Recess depth 44.00 mm Rated voltage 415.00 V Rated current 20.00 A Rated impulse-withstand voltage (Uimp) 6.00 kV Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 20.00 kA Tripping characteristic (type/curve) C Number of protected poles 2.00 Width in number of modular spacings 2.00 Pollution degree 3.00 Current limiting class 3.00 Over voltage category 4.00 Number of poles (total) 2.00 Rated insulation voltage Ui 500.00 V Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 10.00 kA Frequency 50.00 – 60.00 Hz Connectable conductor cross section solid-core 1.00 – 25.00 mm² Connectable conductor cross section multi-wired 1.00 – 25.00 mm² Ambient temperature during operating 30.00 – 70.00 °C Suitable for flush-mounted installation No Concurrently switching N-neutral No Additional equipment possible Yes · Technical Data Sheet – Click to Download