Active Arc Fault Detection Rcbo Acti9 Icv40H Arc 1 Pole + Neutral 10 A C Curve 30 Ma Type A-Si 10000 A

Active Arc Fault Detection Rcbo Acti9 Icv40H Arc 1 Pole + Neutral 10 A C Curve 30 Ma Type A-Si 10000 A

£233.50 Incl. VAT

This Acti9 Active iCV40 ARC product is an arc fault detection RCBO. It is a 1P+N with 1 protected pole, 10A In rated current and C tripping curve. The earth leakage protection class is A-SI type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The rated short circuit breaking capacity goes up to 10000A at 230VAC conforming to EN/IEC 61009-2-1 standard and 10kA at 230VAC conforming to EN/IEC60947-2. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. The Acti9 Active products communicate with the gateway EcoStruxure Panel Server Entry, Universal and Advanced. Its pre alarming system can prevent any overload, earth leakage and overvoltage. It can also measure the voltage, the current and the power. Its 2 unique VisiTrip indicators reduce intervention time by showing the faulty circuit and identifying quickly the type of default. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 250VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 2. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D)73mm. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. This product is compliant with EN/IEC 60898-1, EN/IEC 60947-2, EN/IEC 62606, EN/IEC 61009-1 and EN/IEC 61009-2-1 standard. · · · Poles description 1P + N · · Number of protected poles 1 · · Curve code C · · Neutral position Left

10 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal

Description

Technical Specifications  Technical Specifications Earth leakage circuit breaker/RCBO with auxiliary device Additional equipment attached at delivery Arc fault detection device (AFDD) Degree of protection (IP rating) IP20 Tripping characteristic (type/curve) C Leakage current type A Control voltage type auxiliary equipment AC Number of poles 2 Rated current 10 A Frequency 50 Hz Recess depth 44 mm Rated short-circuit breaking capacity IEC 60947-2 10 kA Rated short-circuit breaking capacity according to EN 61009 10 kA Rated voltage auxiliary device – V Rated switch current auxiliary device – A Pollution degree 2 Rated fault current 0.03 A Over voltage category 3 Current limiting class 3 Rated voltage 230 V Width in number of modular spacings 2 Concurrently switching N-neutral Yes · Technical Data Sheet – Click to Download · Technical Data Sheet – Click to Download · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2194136