Eaton Switch Disconnect On-Off 3Ph Triple Pole+Neutral IP65 20A 400V 50/60Hz

Eaton Switch Disconnect On-Off 3Ph Triple Pole+Neutral IP65 20A 400V 50/60Hz

£52.21 Incl. VAT

Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T0, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, 3 pole + N, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65, Design: surface mounting, Switching angle: 90 °, Motor rating AC-23A, 50 – 60 Hz 400 V: P = 5.5 kW, Rated uninterrupted current: Iu = 20 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3 · · · Emergency switching OFF function · · Lockable in the 0 (OFF) position · · Rated uninterrupted current is specified for maximum cross-section · · IP65 Degree of protection · · Meets IEC/EN 60947, VDE 0660, IEC/EN 60204 and IEC/EN 60947-3 standards

Typically available in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: T0-2-8900/I1/SVB Categories: , , Brand: Product Code: 2500167804

Description

Technical Specifications  Technical Specifications Switch disconnector / isolator Colour control element Red Device construction Complete device in housing Type of control element Door coupling rotary drive Degree of protection (IP), front side IP65 Degree of protection (NEMA) 12 Type of electrical connection of main circuit Screw connection Rated short-time withstand current lcw 0.32 kA Conditioned rated short-circuit current Iq 6 kA Number of switches 1 Rated permanent current Iu 20 A Number of auxiliary contacts as change-over contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as normally closed contact 0 Max. rated operation voltage Ue AC 690 V Rated operation power at AC-23, 400 V 5.5 kW Rated permanent current at AC-21, 400 V 20 A Switching power at 400 V 5.5 kW Rated permanent current at AC-23, 400 V 13.3 A Number of poles 3 Rated operation power at AC-3, 400 V 5.5 kW Rated operating voltage 690 – 690 V Version as maintenance-/service switch Yes Suitable for front mounting 4-hole No Version as main switch Yes Version as safety switch No Interlockable Yes Suitable for distribution board installation No Suitable for intermediate mounting No Suitable for front mounting centre No Motor drive optional No Voltage release optional No Version as reversing switch No Version as emergency stop installation Yes Motor drive integrated No · Technical Data Sheet – Click to Download