Acti9 Icv40 1 Pole + Neutral 32A C Curve 6000 A 30mA Ac Type Residual Current Breaker With Overcurrent Protection (Rcbo)
£283.34 Incl. VAT
This Acti9 iCV40 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 32A In rated current and C tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its 2 unique Visitrip indicators reduce intervention time by showing the faulty circuit and identifying quickly the type of default. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50/60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 210g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C. · · · This Acti9 iCV40 is a modular residual current breaker with overcurrent protection (RCBO). · · It is a 1P+N circuit breaker with 1 protected pole and 32A In rated current and C tripping curve. · · The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. · · The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. · · This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards.
4 available – delivery in 1–2 days
Description
Technical Specifications Technical Specifications Earth leakage circuit breaker/RCBO Mounting method DIN rail Tripping characteristic (type/curve) C Rated insulation voltage Ui 400.00 V Recess depth 44.00 mm Rated fault current 0.03 A Rated current 32.00 A Rated voltage 230.00 V Pollution degree 3.00 Rated impulse-withstand voltage (Uimp) 4.00 kV Over voltage category 3.00 Surge current capacity 0.25 kA Number of poles (total) 2.00 Number of protected poles 1.00 Current limiting class 3.00 Width in number of modular spacings 2.00 Rated short-circuit breaking capacity Icn according to EN 61009-1 6.00 kA Rated short-circuit breaking capacity according to EN 61009 6.00 kA Connectable conductor cross section solid-core 1.00 – 16.00 mm² Connectable conductor cross section multi-wired 1.00 – 10.00 mm² Ambient temperature during operating -5.00 – 60.00 °C Concurrently switching N-neutral Yes Suitable for flush-mounted installation No Anti-nuisance tripping version No With interlocking device Yes · Technical Data Sheet – Click to Download