This Acti9 iC40N product is a low voltage miniature circuit breaker (MCB). It is a 1P+N circuit breaker with 1 protected pole and 10A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 230VAC conforming to EN/IEC 60947-2 standard and 6000A at 230VAC conforming to EN/IEC 60898-1 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. The installation and cabling are simplified with clip on function as well as ease of maintenance. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 74mm. The weight is 120g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C. · · · Poles description 1 Pole and Neutral · · Neutral position Left · · [In] rated current 10 A · · Network type AC · · This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation.
Out of stock
Description
Technical Specifications Technical Specifications Miniature circuit breaker (MCB) Rated current 10.00 A Rated insulation voltage Ui 400.00 V Recess depth 44.00 mm Width in number of modular spacings 1.00 Rated voltage 230.00 V Number of protected poles 1.00 Over voltage category 3.00 Current limiting class 3.00 Pollution degree 3.00 Rated impulse-withstand voltage (Uimp) 4.00 kV Rated short-circuit breaking capacity Icn EN 60898 at 400 V – kA Connectable conductor cross section multi-wired 1.00 – 10.00 mm² Connectable conductor cross section solid-core 1.00 – 16.00 mm² Frequency 50.00 – 60.00 Hz Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V – kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 10.00 kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6.00 kA Number of poles (total) 2.00 Ambient temperature during operating -25.00 – 70.00 °C Suitable for flush-mounted installation No Concurrently switching N-neutral Yes Additional equipment possible Yes