Schneider MCB Acti9 iC60H Single Pole Type B 20A 15kA
£20.70 Incl. VAT
This Acti9 iC60H is a multi-standard, low voltage, miniature circuit breaker (MCB) with double tunnel terminals. This MCB protects circuit against short circuit and overload current. – 1P circuit breaker with 1 protected pole, 20A rated current and B tripping curve. – Rated short circuit breaking capacity goes up to 15kA at 220VAC to 240VAC – conforming to EN/IEC 60947-2 standard; or 10kA at 240VAC – conforming to EN/IEC 60898-1 standard. – Industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2 compliant. – VisiTrip indicator reduces intervention time by showing the faulty circuit. – VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. – Improved service life with fast closing mechanism independent of manual operation. – Electrical endurance going up to 10,000 cycles and mechanical endurance going up to 20000 cycles. – Ui rated insulation voltage is 500VAC. – Limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. – Can be clipped on a DIN rail. – Width: 2 pitches of 9mm. – Pollution degree: 3. – Colour: white (RAL9003). – Dimensions: (W) 18mm x (H) 85mm x (D) 78.5mm. – Weight: 0.125kg. – IP20 degree of protection (as per IEC/EN 60529) on its terminals. – Operating temperature: -35°C to 70°C. – Storage temperature: -40°C to 85°C. · · · Green Premium Product · · Thermal-magnetic trip unit technology · · B Curve · · Clip-on DIN rail mounting mode · · 20000 cycle mechanical durability · · 10000 cycle electrical durability · · Padlockable · · Its fast closing mechanism independent of manual operation improves its service life. · · It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ui rated insulation voltage is 500VAC.
9 available – delivery in 1–2 days
Description
Technical Specifications Technical Specifications Miniature circuit breaker (MCB) Rated current 20 A Recess depth 44.5 mm Rated insulation voltage Ui 500 V Tripping characteristic (type/curve) B Number of protected poles 1 Current limiting class 3 Over voltage category 4 Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 15 kA Rated impulse-withstand voltage (Uimp) 6 kV Rated voltage 240 V Rated short-circuit breaking capacity Icn EN 60898 at 230 V 10 kA Number of poles (total) 1 Pollution degree 3 Width in number of modular spacings 1 Frequency 50 – 60 Hz Connectable conductor cross section solid-core 1 – 25 mm² Connectable conductor cross section multi-wired 1 – 16 mm² Ambient temperature during operating 35 – 70 °C Concurrently switching N-neutral No Suitable for flush-mounted installation No Additional equipment possible Yes · Technical Data Sheet – Click to Download