Schneider RCCB Four Pole Class A 63A 30mA 380/415V AC 50/60Hz
£410.66 Incl. VAT
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with 63A In rated current, 30mA earth leakage sensitivity and A type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 15000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C. · · · Complete with VisiSafe, which helps to ensure the ultimate in safety for both operation and maintenance work · · Class-2 insulation: ensures continuous protection for both operators and unqualified personnel · · Complete with VisiTrip: detects faulty outgoers quickly and reduces intervention time · · Coordination with Acti 9 and Multi 9 MCBs · · Fully compliant with standard IEC EN 61008-1 · · Easy to install with quick, ergonomic and secure IP20B terminal shutters · · Fully robust connections which provide twice the standard tightening torque · · Environmentally friendly: made from 100% recyclable and recoverable materials. · · Designed for industrial and commercial buildings · · The Ue operational voltage is 380VAC to 415VAC.
Out of stock
Description
Technical Specifications Technical Specifications Residual current circuit breaker (RCCB) Rated current 63 A Rated voltage 415 V Number of poles 4 Recess depth 73.5 mm Surge current capacity 0.25 kA Connectable conductor cross section solid-core 1 – 35 mm² Width in number of modular spacings 4 Short-circuit breaking capacity (Icw) 10 kA Rated fault current 30 A Rated impulse-withstand voltage (Uimp) 6 kV Pollution degree 3 Rated insulation voltage Ui 500 V Connectable conductor cross section multi-wired 1 – 25 mm² Ambient temperature during operating -25 – 60 °C Selective protection No Short-time delayed tripping No With interlocking device No Additional equipment possible Yes · Technical Data Sheet – Click to Download