RCCB Double Pole Class AC 40A 30mA 36 x 91 x 73.5mm

RCCB Double Pole Class AC 40A 30mA 36 x 91 x 73.5mm

£164.75 Incl. VAT

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, AC type protection class and a 30mA earth leakage sensitivity. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C. · · · This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). · · It is a 2P circuit breaker with In rated current of 40A, AC type protection class and a 30mA earth leakage sensitivity. · · This product protects against electrical shock by direct or indirect contact and fire hazards. · · It performs the function of disconnection of electrical circuits in case of earth fault. · · Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. · · This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance · · This product is compliant with EN/IEC 61008-1 standard. · · The (Im/I?m) rated breaking and making short circuit capacity is 1500A. The (Inc/I?c) conditional rated short circuit current is 10kA. · · The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. · · The Ue operational voltage is 220VAC to 240VAC.

16 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9R41240 Categories: , , Brand: Part Number: 2500584132

Description

Technical Specifications  Technical Specifications Residual current circuit breaker (RCCB) Number of poles 2 Pollution degree 3 Recess depth 73.5 mm Rated impulse-withstand voltage (Uimp) 6 kV Rated insulation voltage Ui 500 V Rated fault current 30 A Short-circuit breaking capacity (Icw) 10 kA Surge current capacity 0.25 kA Rated voltage 240 V Short-time delayed tripping No Selective protection No Ambient temperature during operating -5 – 60 °C Connectable conductor cross section multi-wired 1 – 25 mm² Connectable conductor cross section solid-core 1 – 35 mm² Rated current 40 A Width in number of modular spacings 2 With interlocking device No Additional equipment possible Yes · Technical Data Sheet – Click to Download