Schneider RCCB Iid Double Pole Class A 40A 30Ma

Schneider RCCB Iid Double Pole Class A 40A 30Ma

£204.20 Incl. VAT

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, A type protection class and a 30mA earth leakage sensitivity. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C. · · · Complete with VisiSafe, which helps to ensure the ultimate in safety for both operation and maintenance work · · Class-2 insulation: ensures continuous protection for both operators and unqualified personnel · · Complete with VisiTrip: detects faulty outgoers quickly and reduces intervention time · · Coordination with Acti 9 and Multi 9 MCBs · · Fully compliant with standard IEC EN 61008-1 · · Easy to install with quick, ergonomic and secure IP20B terminal shutters · · Fully robust connections which provide twice the standard tightening torque · · Environmentally friendly: made from 100% recyclable and recoverable materials. · · Designed for industrial and commercial buildings · · The Ue operational voltage is 220VAC to 240VAC.

2 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9R21240 Categories: , , Brand: Part Number: 2500685317

Description

Technical Specifications  Technical Specifications Residual current circuit breaker (RCCB) Recess depth 73.5 mm Rated current 40 A Rated impulse-withstand voltage (Uimp) 6 kV Pollution degree 3 Short-circuit breaking capacity (Icw) 10 kA Width in number of modular spacings 2 Rated voltage 230 V Number of poles 2 Rated insulation voltage Ui 500 V Rated fault current 30 A Surge current capacity 0.25 kA Connectable conductor cross section solid-core 1 – 35 mm² Connectable conductor cross section multi-wired 1 – 25 mm² Ambient temperature during operating -25 – 60 °C Selective protection No Additional equipment possible Yes Short-time delayed tripping No With interlocking device No · Technical Data Sheet – Click to Download