RCBO SP Class A Type B 32A 30mA 10kA Plug-On

RCBO SP Class A Type B 32A 30mA 10kA Plug-On

£53.89 Incl. VAT

The Schneider LoadCentre KQ SEE132B03 is a 32 amp 30 milliamp single pole RCBO. This Schneider LoadCentre KQ RCBO has a click-in busbar for speed of installation and guaranteed connection, has a 10kA breaking capacity and has a trip free mechanism that operates even when the toggle is locked on. The LoadCentre KQ MCB’s are lockable in the on or off position and is suitable for any Schneider Loadcentre KQ A and B type distribution boards. · · · Compatible with Loadcentre KQ B Type boards · · Other RCBO options available · · Fast installation with click-in busbar · · The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. · · Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. · · Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. · · Its fast closing mechanism independent of manual operation improves its service life. · · This product is compliant with IEC 61009-2-2 and IEC 61009-1 standard. · · It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ue operational voltage is 150VAC to 230VAC.

174 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: SEE132B03 Categories: , , Brand: Part Number: 2500577522

Description

Technical Specifications  Technical Specifications Earth leakage circuit breaker/RCBO Mounting method DIN rail Tripping characteristic (type/curve) B Recess depth 70 mm Rated insulation voltage Ui 400 V Rated current 32 A Rated voltage 230 V Pollution degree 3 Over voltage category 3 Rated impulse-withstand voltage (Uimp) 4 kV Number of poles (total) 2 Current limiting class 3 Connectable conductor cross section multi-wired 1 – 16 mm² Connectable conductor cross section solid-core 1 – 16 mm² Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA Width in number of modular spacings 2 Rated fault current 0.03 A Number of protected poles 1 Surge current capacity 0.25 kA Ambient temperature during operating -25 – 55 °C With interlocking device No Suitable for flush-mounted installation No Anti-nuisance tripping version No Concurrently switching N-neutral Yes · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2200034