Schneider Electric Surge Arrester Modular Triple Pole+Neutral 8Ka 350V Including Remote Transfer

Schneider Electric Surge Arrester Modular Triple Pole+Neutral 8Ka 350V Including Remote Transfer

£388.34 Incl. VAT

IPRD8modular surge arrester, 3p+N, 350V. range: Acti 9 – product name: Acti 9 iPRD – product or component type: surge arrester with pluggable cartridge – device short name: iPRD8 – device application: distribution – surge arrester type: electrical distribution network – earthing system: TN-S, TT – [Uoc] open circuit voltage: 10 kV type 3 common mode N/PE, 10 kV type 3 differential mode L/N. · · · This Acti9 iPRD8 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. · · The Up Voltage protection level in CM common mode (between phase and neutral) is 1.1kV. · · The iPRD8r ensures secondary protection of loads to be protected and is placed in cascade with the incoming surge arresters. · · This surge arrester is required when the loads to be protected are at a distance of more than 10 m from the incoming surge arrester. · · 3P + N – 350V · · The Uc maximum continuous operating voltage in DM common mode (between phase and neutral) is 260VAC. · · The Uc maximum continuous operating voltage in DM common mode (between earth and neutral) is 350VAC. · · The Up Voltage protection level in CM common mode (between phase and neutral) is 1.1kV.

Typically available in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9L08600 Category: Brand: Product Code: 2500577714

Description

Technical Specifications  Technical Specifications Surge protection device for power supply systems Max. conductor cross section solid (solid, stranded) 35 mm² Max. conductor cross section flexible (fine-strand) 35 mm² Max. PV-voltage – V Nominal voltage DC – V Nominal voltage AC 400 V Voltage protection level N-PE 1.1 kV Max. continuous voltage DC – V Voltage protection level L-N 1.1 kV Voltage protection level 1.2 kV Nominal discharge surge current 8/20 µs (In) 2.5 kA Max. voltage (Uc) 350 V Max. discharge surge current (8/20) 8 kA Short-circuit breaking capacity (Isccr) – kA Number of conductors (without earthing) 3 With remote signalling contact No Integrated backup fuse No System configuration TN No System configuration TN-C No System configuration DC No System configuration IT No System configuration other No System configuration TN-S Yes System configuration TN-C-S No Type / Test class 2 Yes System configuration TT Yes · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2224955