Schneider Electric Vigi IC60 Earth Leakage Add-On Block 1 Pole + Neutral 63A 100mA – A Type
£199.52 Incl. VAT
This Acti9 Vigi iC60 is a modular add-on residual current devices. It is a 1P + N, rated current is 63A, operating voltage is 240VAC according to IEC 61009-1. The earth leakage protection class is A type with a sensitivity of 100mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with Acti9 iC60 circuit breaker to provide protection of persons and protection of installations. This product is compliant with EN 61009-1 and IEC 61009-1 standard. The Ue rated operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 4. The dimensions are (W) 54mm x (H) 91mm x (D) 73.5mm. The weight is 0.165kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature -5°C to +60°C. The storage temperature is -40°C to +85°C. · · · The absolute safety for earth leakage protection in final distribution · · Greater continuity of service with VisiTrip · · Greater electrical immunity with Si type (Super immune), · · Easy to install with robust terminal connections · · Environmentally friendly with 100% recyclable & recoverable materials · · Compliance with standard IEC EN 61009-1, certified by national official authorities · · Trip Sensitivity: 100 Ma
✓ In stock – Delivery in 1–2 days
Description
Technical Specifications Technical Specifications Residual current circuit breaker (RCCB) module Max. delay time 0.00 ms Surge current capacity 0.25 kA Rated insulation voltage Ui 500.00 V Number of poles 2.00 Nominal current 63.00 A Rated impulse-withstand voltage (Uimp) 6.00 kV Pollution degree 3.00 Nominal voltage 230.00 – 240.00 V Connectable conductor cross section solid-core 1.00 – 35.00 mm² Rated fault current 0.10 – 0.10 A Connectable conductor cross section multi-wired 1.00 – 25.00 mm² Ambient temperature during operating 5.00 – 60.00 °C Rated fault current adjustable No Delay adjustable No With interlocking device No Anti-nuisance tripping version No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2190549






