IC60H Earth Leakage Circuit Breaker 1 Pole + Neutral C-Curve 32A 30mA 110V
£179.86 Incl. VAT
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 32A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with BS EN 61009-1 and IEC 61009-2-2 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 110VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is white (RAL9003). The dimensions are (W) 18mm x (H) 110mm x (D) 77.5mm. The weight is 205g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C. · · · Padlockable in ON/OFF positions · · Clip-on DIN rail mounting mode · · 20000 cycle mechanical durability · · 5000 cycle electrical durability · · Compact design is perfect for space-saving solutions · · Green Premium Product · · Trip Sensitivity: 30 Ma
44 available – delivery in 1–2 days
Description
Technical Specifications Technical Specifications Earth leakage circuit breaker/RCBO Rated current 32.00 A Rated voltage 110.00 V Rated impulse-withstand voltage (Uimp) 4.00 kV Width in number of modular spacings 1.00 Current limiting class 3.00 Recess depth 45.00 mm Rated insulation voltage Ui 400.00 V Rated short-circuit breaking capacity Icn according to EN 61009-1 10.00 kA Rated fault current 0.03 A Number of poles (total) 2.00 Surge current capacity 0.25 kA Pollution degree 3.00 Over voltage category 4.00 Number of protected poles 1.00 Connectable conductor cross section solid-core 1.00 – 25.00 mm² Connectable conductor cross section multi-wired 1.00 – 16.00 mm² Ambient temperature during operating -15.00 – 60.00 °C Concurrently switching N-neutral Yes Suitable for flush-mounted installation No Anti-nuisance tripping version No With interlocking device No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2199803