Acti9 iPRD40 Modular Surge Arrester 1P+N 350V

Acti9 iPRD40 Modular Surge Arrester 1P+N 350V

£382.78 Incl. VAT

This Acti9 iPRD40 surge arrester protects 1P+N installations. It allows quick replacement of damaged cartridges. Modular design (cartridge type) DIN rail mounted The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Ue rated operational voltage is 230VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 36mm x (H) 85mm x (D) 69mm. The weight is 0.211kg. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard. · · · A complete surge protection range · · Modular design (cartridge type) · · DIN rail mounted · · Clip-on · · 1 Pole + N · · The Uc maximum continuous operating voltage in DM common mode (between phase and neutral) is 260VAC. · · The Uc maximum continuous operating voltage in DM common mode (between earth and neutral) is 350VAC. · · The Up Voltage protection level in CM common mode (between phase and neutral) is 1.4kV.

7 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9L40500 Categories: , Brand: Part Number: 2500866978

Description

Technical Specifications  Technical Specifications Surge protection device for power supply systems Max. conductor cross section solid (solid, stranded) 35 mm² Max. conductor cross section flexible (fine-strand) 35 mm² Max. discharge surge current (8/20) 40 kA Short-circuit breaking capacity (Isccr) – kA Nominal voltage AC 350 V Nominal voltage DC – V Max. continuous voltage DC – V Voltage protection level L-N 1.4 kV Voltage protection level 1.4 kV Number of conductors (without earthing) 1 Integrated backup fuse No System configuration DC No With remote signalling contact No Max. PV-voltage – V Max. voltage (Uc) 350 V Voltage protection level N-PE 1.4 kV Nominal discharge surge current 8/20 µs (In) 15 kA System configuration TN-C-S No Type / Test class 2 Yes System configuration TN-C No System configuration other No System configuration IT No System configuration TN No System configuration TN-S Yes System configuration TT Yes · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2224955