Miniature Circuit Breaker (MCB) 16A 1 Pole Characteristic: Type D 10 Ka

Miniature Circuit Breaker (MCB) 16A 1 Pole Characteristic: Type D 10 Ka

£21.73 Incl. VAT

This is a 16-ampere, 1-pole, D-type miniature circuit breaker (MCB). It has a 230-440V AC voltage rating and a 10kA interrupting rating. Part of Eaton’s xEffect series of MCBs.This is a single-pole breaker, meaning that it protects one circuit at a time. It has a 16-ampere rating, which means that it can safely carry a current of up to 16 amperes. It also has a 10kA short-circuit rating, which means that it can safely interrupt a short-circuit current of up to 10 kA.This is a safe and reliable way to protect electrical circuits. It is a valuable tool for any electrician or facility manager. · · · Number Of Poles (Total) 1 · · Release Characteristic D · · Amperage Rating 16A · · Voltage Type Ac · · Acti 9 is easy to install and environmentally friendly. Example: Its components are 100% recyclable and recoverable. · · Flexible, upgradeable solutions and simple operations · · Optimised design time, in particular for lighting solutions in buildings. · · Total coordination guaranteed by Schneider Electric. · · The electrical endurance under AC1 category is over 10exp5 switchning operations. · · The type of excitation is analog (ou analogue) with single function. The device is flashing during time delay.

Out of stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: 168063 Categories: , , Brand: Part Number: 2500607259

Description

Technical Specifications  Technical Specifications Miniature circuit breaker (MCB) Degree of protection (IP rating) IP20 Voltage type AC Recess depth 70.5 mm Rated current 16 A Tripping characteristic (type/curve) D Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 10 kA Current limiting class 3 Rated insulation voltage Ui 440 V Power loss 2.3 W Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 10 kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6 kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V 6 kA Rated impulse-withstand voltage (Uimp) 4 kV Over voltage category 3 Connectable conductor cross section solid-core 1 – 25 mm² Frequency 50 – 60 Hz Width in number of modular spacings 1 Rated voltage 230 V Number of protected poles 1 Number of poles (total) 1 Pollution degree 2 Connectable conductor cross section multi-wired 1 – 25 mm² Ambient temperature during operating -25 – 75 °C Concurrently switching N-neutral No Explosion-proof No Additional equipment possible Yes Flush-mounted installation No · Technical Data Sheet – Click to Download