Schneider Electric Tesys Le Enclosed Dol Starter 12A 400V AC Coil
£98.29 Incl. VAT
TeSys enclosed starter with contactor, 3 poles, Ithe 12A 690V, for non-reversing motor applications 5.5kW@400V AC-3. Polycarbonate enclosure providing IP65 / IK07 protection, equipped with a green pushbutton Start (I) and a red pushbutton Stop/Reset (O). It includes a contactor LC1D with a control circuit 400V 50/60Hz. To operate, it must be fitted with a thermal overload relay LRD16 (to be ordered separately). Surface mounting enclosure with screw fixing, 2 knock-outs for cable glands on top and bottom. It conforms to IEC 60947-4-1, Green Premium compliant (RoHS/REACh). · · · TeSys enclosed starter with contactor, 3 poles, Ithe 12A 690V, for non-reversing motor applications 5.5kW@400V AC-3. · · Width: 88mm · · Polycarbonate enclosure providing IP65 / IK07 protection, equipped with a green pushbutton Start (I) and a red pushbutton Stop/Reset (O). · · It includes a contactor LC1D with a control circuit 400V 50/60Hz. · · To operate, it must be fitted with a thermal overload relay LRD16 (to be ordered separately).
Out of Stock
Description
Technical Specifications Technical Specifications Motor starter/Motor starter combination Width 88 mm Height 166 mm Number of command positions 2 Depth 128.5 mm Rated operation power at AC-3, 400 V 5.5 kW Number of auxiliary contacts as normally open contact 0 Rated operation current at AC-3, 400 V 12 A Number of indicator lights 0 Ambient temperature, upper operating limit 40 °C Rated operation power at AC-3, 230 V, 3-phase 3 kW Rated operation current Ie 12 A Number of auxiliary contacts as normally closed contact 0 Rated power, 575 V, 60 Hz, 3-phase 7.5 kW Rated power, 460 V, 60 Hz, 3-phase 5.5 kW Rated conditional short-circuit current, type 1, 480 Y/277 V – A Rated conditional short-circuit current, type 1, 600 Y/347 V – A Rated conditional short-circuit current, type 2, 230 V – A Rated conditional short-circuit current, type 2, 400 V – A Rated control supply voltage at DC – – – V Overload release current setting – – – A Rated control supply voltage at AC 50 Hz 400 – 400 V Rated control supply voltage at AC 60 Hz 400 – 400 V With fuse No External reset possible Yes Suitable for emergency stop No Supporting protocol for PROFIsafe No Supporting protocol for SafetyBUS p No Supporting protocol for ASI No Supporting protocol for Data-Highway No Supporting protocol for DeviceNet No Supporting protocol for SUCONET No Supporting protocol for LON No Supporting protocol for SERCOS No Supporting protocol for INTERBUS-Safety No Supporting protocol for other bus systems No With short-circuit release No Supporting protocol for PROFINET IO No Temperature compensated overload protection No Supporting protocol for PROFINET CBA No Supporting protocol for Foundation Fieldbus No Supporting protocol for EtherNet/IP No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for DeviceNet Safety No With transformer No Rail mounting possible No Supporting protocol for TCP/IP No Supporting protocol for PROFIBUS No Supporting protocol for CAN No Supporting protocol for INTERBUS No Supporting protocol for MODBUS No · Technical Data Sheet – Click to Download





