Schneider Electric Tesys Le Enclosed Dol Starter 18A 415V AC Coil
£167.36 Incl. VAT
TeSys LE, enclosed DOL starter, 18A, 415 V AC coil. range: TeSys – product name: TeSys LE – device short name: LE1D – device application: standard – utilisation category: AC-3 – device composition: contactor, thermal overload relay to be ordered separately – control type: push-button start green I, push-button stop/reset red O. · · · Polycarbonate enclosure provides high level protection against water, dust and mechanical compact · · Environmentally friendly product · · Good performance on motor protection against overload, work with overload relay · · Easy to use with ON/OFF pushbuttons at the front · · Multiple resetting methods: manual & remotely
Out of Stock
Description
Technical Specifications Technical Specifications Motor starter/Motor starter combination Width 101.00 mm Depth 153.50 mm Height 201.00 mm Number of command positions 2.00 Number of auxiliary contacts as normally open contact 0.00 Rated operation power at AC-3, 400 V 7.50 kW Number of auxiliary contacts as normally closed contact 0.00 Rated operation current Ie 18.00 A Number of indicator lights 0.00 Rated operation current at AC-3, 400 V 18.00 A Ambient temperature, upper operating limit 40.00 °C Rated operation power at AC-3, 230 V, 3-phase 4.00 kW Rated power, 575 V, 60 Hz, 3-phase 11.00 kW Rated power, 460 V, 60 Hz, 3-phase 7.50 kW Rated conditional short-circuit current, type 2, 400 V – A Rated conditional short-circuit current, type 2, 230 V – A Rated conditional short-circuit current, type 1, 480 Y/277 V – A Rated conditional short-circuit current, type 1, 600 Y/347 V – A Rated control supply voltage at AC 50 Hz 415.00 – 415.00 V Rated control supply voltage at AC 60 Hz 415.00 – 415.00 V Overload release current setting – – – A Rated control supply voltage at DC – – – V External reset possible Yes Suitable for emergency stop No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for DeviceNet Safety No Supporting protocol for PROFIsafe No Supporting protocol for PROFINET CBA No Supporting protocol for Foundation Fieldbus No Supporting protocol for EtherNet/IP No With fuse No Supporting protocol for SafetyBUS p No With transformer No Rail mounting possible No Supporting protocol for TCP/IP No Supporting protocol for PROFIBUS No Supporting protocol for CAN No Supporting protocol for INTERBUS No Supporting protocol for MODBUS No Supporting protocol for ASI No Supporting protocol for Data-Highway No Supporting protocol for DeviceNet No Supporting protocol for SUCONET No Supporting protocol for LON No Supporting protocol for SERCOS No Supporting protocol for INTERBUS-Safety No Supporting protocol for other bus systems No With short-circuit release No Temperature compensated overload protection No Supporting protocol for PROFINET IO No · Technical Data Sheet – Click to Download





