Schneider Electric TeSys D changeover contactor, 4p(4 NO), AC-1, <= 440 V 25A, 48 V AC co
£179.94 Incl. VAT
TeSys D changeover contactor, 4p(4 NO), AC-1, <= 440 V 25A, 48 V AC coil. range: TeSys – product name: TeSys D – product or component type: changeover contactor – device short name: LC2D – contactor application: resistive load – utilisation category: AC-1 – device presentation: preassembled, with prewired power connections – poles description: 4P – pole contact composition: 4 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 25 A at <= 60 °C for power circuit – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A DC for signalling circuit conforming to IEC 60947-5-1 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 105 A <= 40 °C 10 s power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 210 A <= 40 °C 1 s power circuit, 30 A <= 40 °C 10 min power circuit, 61 A <= 40 °C 1 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at <= 690 V coordination type 2 for power circuit, 40 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – protective cover: with – interlocking type: mechanical – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end, power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, power circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end, power circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, power circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end – tightening torque: control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm, control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2, power circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm, power circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 – operating time: 12…22 ms closing, 4…19 ms opening – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 15 Mcycles.
Out of Stock
Description
Technical Specifications Technical Specifications Combination of contactors Degree of protection (IP rating) IP20 Function Changeover contactor Type of electrical connection of main circuit Screw connection Type of electrical connection for auxiliary- and control current circuit Screw connection Voltage type for actuating AC Voltage type (operating voltage) AC Number of auxiliary contacts as change-over contact – Number of auxiliary contacts as normally closed contact 1 Number of auxiliary contacts as normally open contact 1 Rated operation power NEMA – kW Number of normally closed contacts as main contact 2 Rated operation power at AC-3, 400 V – kW Rated operation current Ie at AC-3, 400 V – A Rated operation current Ie at AC-1, 400 V 25 A Number of main contacts as normally open contact 2 Depth 90 mm Height 85 mm Width 90 mm Rated control supply voltage at AC 50 Hz 48 – 48 V Rated control supply voltage at AC 60 Hz 48 – 48 V Rated control supply voltage at DC – V Operating voltage at AC 50 Hz 440 – 440 V Operating voltage at DC – – – V Operating voltage at AC 60 Hz 440 – 440 V Rail mounting possible Yes · Technical Data Sheet – Click to Download