TeSys LE, enclosed DOL starter, 8…11,5A, 415 V AC coil. range: TeSys – product name: TeSys LE – device short name: LE1M – device application: standard – utilisation category: AC-3 – device composition: contactor, earth terminal, neutral terminal, thermal overload relay – motor power kW: 2.2 kW at 220/230 V AC 50/60 Hz, 2.2 kW at 240 V AC 50/60 Hz, 4 kW at 380/400 V AC 50/60 Hz, 4 kW at 415 V AC 50/60 Hz – control type: push-button start green I, push-button stop/reset red O. · · · Polycarbonate enclosure provides high level protection against water, dust and mechanical compact · · Environmentally friendly product · · Good performance on motor protection against overload, work with overload relay · · Easy to use with pushbuttons at the front · · Multiple resetting methods: manual & remotely

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal

Description

Technical Specifications  Technical Specifications Motor starter/Motor starter combination Width 78.00 mm Depth 108.00 mm Height 160.00 mm Number of command positions 2.00 Rated operation power at AC-3, 400 V 4.00 kW Number of auxiliary contacts as normally open contact 0.00 Number of auxiliary contacts as normally closed contact 0.00 Rated operation current Ie 11.50 A Rated operation current at AC-3, 400 V 11.50 A Number of indicator lights 1.00 Rated operation power at AC-3, 230 V, 3-phase 2.20 kW Ambient temperature, upper operating limit 40.00 °C Rated power, 460 V, 60 Hz, 3-phase 5.50 kW Rated power, 575 V, 60 Hz, 3-phase 7.50 kW Rated conditional short-circuit current, type 2, 400 V – A Rated conditional short-circuit current, type 2, 230 V – A Rated conditional short-circuit current, type 1, 480 Y/277 V – A Rated conditional short-circuit current, type 1, 600 Y/347 V – A Rated control supply voltage at AC 50 Hz 415.00 – 415.00 V Rated control supply voltage at AC 60 Hz 415.00 – 415.00 V Overload release current setting 8.00 – 11.50 A Rated control supply voltage at DC – – – V Suitable for emergency stop No With transformer No Rail mounting possible No Supporting protocol for TCP/IP No Supporting protocol for PROFIBUS No Supporting protocol for CAN No Supporting protocol for INTERBUS No Supporting protocol for MODBUS No Supporting protocol for ASI No Supporting protocol for Data-Highway No Supporting protocol for DeviceNet No Supporting protocol for SUCONET No Supporting protocol for LON No Supporting protocol for INTERBUS-Safety No Supporting protocol for SERCOS No Supporting protocol for other bus systems No Supporting protocol for PROFIsafe No Supporting protocol for SafetyBUS p No With short-circuit release No Supporting protocol for PROFINET IO No Supporting protocol for PROFINET CBA No Supporting protocol for Foundation Fieldbus No Supporting protocol for EtherNet/IP No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for DeviceNet Safety No With fuse No Temperature compensated overload protection Yes External reset possible Yes · Technical Data Sheet – Click to Download