Schneider Electric Surge Arrester Iquick Prd20R Triple Pole+Neutral 20Ka Remote Transfer

Schneider Electric Surge Arrester Iquick Prd20R Triple Pole+Neutral 20Ka Remote Transfer

£719.47 Incl. VAT

This Acti9 iQuick PRD20r surge arrester protects 3P+N residential and larger buildings installations against indirect transient overvoltages. This Type 2 device autoprotected by an integrated circuit-breaker is recommanded for moderate risk level in incoming panel board. It offers remote reporting of the -cartridge must be changed- message. This prewired surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It incorporates its end of life safety disconnector. The Isc integrated breaking capacity is 25kA. This Acti9 iQuick PRD20r is compatible with TT and TN-S earthing system. The Imax maximum discharge current is 20kA. The In nominal discharge current is 5kA. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in common mode is 264VAC between neutral and earth, and is 350VAC between phase and earth. The Up Voltage protection level in differential mode (between phase and neutral) is below or equal to 1.5kV. The Up Voltage protection level in common mode is below or equal to 1.5kV between phase and earth, or neutral and earth. The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 131.5mm x (H) 103.8mm x (D) 75.9mm. The width in 9mm pitches is 15. The weight is 810g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product complies with IEC/EN 60947-5-1 and EN 61643-11: 2012 and IEC 61643-11: 2011 Type 2 standards. · · · Improved continuity of service and safety · · Certified coordination with disconnection circuit breakers · · Remote monitoring of the protection status · · Simplified installation of the Quick ranges, thanks to the integrated disconnector · · Suitable for any earthing system: TT, TN-S, TN-C and IT · · The Imax maximum discharge current is 20kA. The In nominal discharge current is 5kA. · · The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. · · The Uc maximum continuous operating voltage in CM common mode (between neutral and earth) is 264VAC. · · The Up Voltage protection level in DM differential mode (between phase and neutral) is below or equal to 1.5kV. · · The Up Voltage protection level in CM common mode (between neutral and earth) is below or equal to 1.5kV.

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9L16297 Categories: , Brand: Product Code: 2500599059

Description

Technical Specifications  Technical Specifications Surge protection device for power supply systems Max. conductor cross section flexible (fine-strand) 25 mm² Short-circuit breaking capacity (Isccr) – kA Max. conductor cross section solid (solid, stranded) 25 mm² Max. PV-voltage – V Max. discharge surge current (8/20) 20 kA Max. continuous voltage DC – V Nominal voltage AC 400 V Nominal discharge surge current 8/20 µs (In) 5 kA Voltage protection level L-N 1.5 kV Voltage protection level N-PE 1.5 kV Nominal voltage DC – V Number of conductors (without earthing) 3 Max. voltage (Uc) 350 V Voltage protection level 1.5 kV With remote signalling contact Yes System configuration other No System configuration TN-S Yes System configuration TN-C-S No Type / Test class 2 Yes System configuration TN No System configuration TN-C No System configuration DC No System configuration IT No Integrated backup fuse No System configuration TT Yes · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2224902