Schneider Electric Multi9 - C60N - MCB - 2P - 40 A - D Curve - 415 V - 10 kA

Schneider Electric Multi9 – C60N – MCB – 2P – 40 A – D Curve – 415 V – 10 kA

£95.77 Incl. VAT

Multi9™ is a range of DIN rail modular devices, a solution offering great performance. Multi9 range is a Schneider Electric global offer dedicated to equipment manufacturers (OEMs), meeting the major standards for industry applications. Designed to meet your needs for most types of machines, offering a wide range of modular devices it provides protection, signalling functions and accessories. · · · This Multi9 C60N is a low voltage miniature circuit breaker (MCB). · · It is a 2P circuit breaker with 2 protected poles, 40A rated current and D tripping curve. · · The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard. · · This product complies with industrial standard EN/IEC 60947-2. · · It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. · · This product protects from short circuit, earth leakage and overload. · · Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. · · This product is dedicated for original equipment manufacturers (OEM) and control panel builders. · · It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC.

In stock – Delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: M9F12240 Categories: , , Brand: Product Code: 2501537562

Description

Technical Specifications  Technical Specifications Miniature circuit breaker (MCB) Tripping characteristic (type/curve) D Rated current 40 A Recess depth 44 mm Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 20 kA Rated impulse-withstand voltage (Uimp) 6 kV Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 10 kA Over voltage category 4 Number of poles (total) 2 Rated insulation voltage Ui 500 V Pollution degree 3 Current limiting class 3 Number of protected poles 2 Width in number of modular spacings 2 Rated voltage 415 V Frequency 50 – 60 Hz Connectable conductor cross section solid-core 1 – 25 mm² Connectable conductor cross section multi-wired 1 – 25 mm² Ambient temperature during operating -30 – 70 °C Concurrently switching N-neutral No Additional equipment possible Yes · Technical Data Sheet – Click to Download