Siemens Digital Monitoring Relay Current Monitoring, 22.5 Mm Von 0.1 To 10 A AC/DC

Siemens Digital Monitoring Relay Current Monitoring, 22.5 Mm Von 0.1 To 10 A AC/DC

£209.09 Incl. VAT

Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3522-1AL20, 3UG3522-1AG20 and 3UG3522-1AC48-0AA1 Current monitoring relay with digital setting SIRIUS 3UG4 for monitoring currents for overshooting and undershooting, e.g. for ensuring the functionality of electrical loads or for open-circuit monitoring. Worldwide use thanks to international certificates. The relay is variably adjustable to overshoot, undershoot or window monitoring. Delay times and RESET behavior are freely parameterizable. Less space required in the control cabinet thanks to slim design. Reliable diagnostics due to display of ACTUAL value and status messages. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. In addition, they are available in various voltages, and optionally with IO-Link. The comprehensive range of accessories, such as unit labeling plates, push-in lugs and cover caps, is standardized for all relays. SIRIUS relays – one range for every application. · · · Digital monitoring relay current monitoring, 22.5 mm von 0.1 to 10 A AC/DC

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: 3UG4622-1AW30 Categories: , Brand: Product Code: 1050447362

Description

Technical Specifications  Technical Specifications Current monitoring relay Type of electric connection Screw connection Width 22.5 mm Number of contacts as normally open contact 0 Number of contacts as normally closed contact 0 Max. permitted off-delay time 20 s Max. permitted delay-on energization time 20 s Min. adjustable delay-on energization time 0.1 s Min. adjustable off-delay time 0.1 s Height 92 mm Number of contacts as change-over contact 1 Current measurement range 0.05 – 15.0 A Depth 91 mm Single-phase hysteresis possible No With detachable clamps Yes Three-phase under current possible No Three-phase over current possible No Curent transformer No Three-phase hysteresis possible No Single-phase under current possible Yes Single-phase over current possible Yes Contains function DC-voltage under current Yes Contains function DC-voltage over current Yes Function DC-current hysteresis Yes