Siemens ET 200 Pro RSE HF Reversing Starter High Feature HAN Q4/2-HAN Q8/0
£758.84 Incl. VAT
ET 200pro RSE HF Reversing starter High Feature Mechanical switching Electronic overload protection AC-3, 0.9 kW / 400 V 0.15 A…2.00 A without brake contact 4 DI Han Q4/2 – Han Q8/0 Motor starters SIMATIC ET 200pro for operational switching of three-phase motors in the field, with short-circuit and overload protection and for fully TIA-integrated, highly automated applications, for example in conveyor systems. The multifunctional motor starters are fully integrated in the ET 200pro distributed I/O system. The fast and comprehensive configuration takes place in the TIA Portal. Cabinet-free use, thanks to the high IP65/67 degree of protection. Integrated communication via PROFIBUS and PROFINET. Thanks to the wide setting range, there is less variety of devices which means reduced costs for stock keeping and configuration. The easy installation by means of a wiring bus and plug-in technology facilitates fast replacement of the motor starters and increases the availability of the plant. The Motor Starter ES software is available for configuration, commissioning, operation and diagnostics. PROFIenergy supports active and efficient energy management. The devices are approved for worldwide use (e.g. IEC, CCC and UL/CSA) and are IE3/IE4-ready. Available as direct-on-line or reversing starter with various motor current ranges, as standard or High-Feature versions (including soft start function). As an option, a repair switch module can be used in order to guarantee a secure isolation for all downstream motor starters in the event of repair work. In addition, there is a fail-safe repair switch and a disconnecting module for fail-safe applications. ET 200pro motor starters – compact and smart.
Out of Stock
Description
Technical Specifications Technical Specifications Motor starter/Motor starter combination Voltage type for actuating DC Kind of motor starter Reversing starter Type of electrical connection of main circuit Flat plug-in connection Release class CLASS 10 Coordination class according to IEC 60947-4-3 Class 1 Degree of protection (IP rating) IP65 Width 110 mm Number of auxiliary contacts as normally closed contact – Number of command positions – Number of auxiliary contacts as normally open contact – Rated operation power at AC-3, 400 V 0.9 kW Rated operation power at AC-3, 230 V, 3-phase – kW Number of indicator lights – Rated power, 460 V, 60 Hz, 3-phase – kW Rated power, 575 V, 60 Hz, 3-phase – kW Rated conditional short-circuit current, type 1, 480 Y/277 V – A Rated conditional short-circuit current, type 1, 600 Y/347 V – A Rated conditional short-circuit current, type 2, 230 V – A Rated conditional short-circuit current, type 2, 400 V – A Ambient temperature, upper operating limit – °C Rated operation current Ie 2 A Rated operation current at AC-3, 400 V 2 A Height 230 mm Depth 150 mm Rated control supply voltage at AC 50 Hz – V Rated control supply voltage at AC 60 Hz – V Overload release current setting 0.15 – 2 A Rated control supply voltage at DC 20.4 – 28.8 V With transformer No Rail mounting possible No Suitable for emergency stop No Supporting protocol for TCP/IP No Supporting protocol for PROFIBUS No Supporting protocol for CAN No Supporting protocol for INTERBUS No Supporting protocol for MODBUS No Supporting protocol for Data-Highway No Supporting protocol for DeviceNet No Supporting protocol for SUCONET No Supporting protocol for LON No Supporting protocol for SERCOS No Supporting protocol for INTERBUS-Safety No Supporting protocol for other bus systems No Supporting protocol for ASI No Temperature compensated overload protection No Supporting protocol for PROFINET IO No Supporting protocol for PROFINET CBA No Supporting protocol for Foundation Fieldbus No Supporting protocol for EtherNet/IP No With fuse No With short-circuit release Yes Supporting protocol for AS-Interface Safety at Work No Supporting protocol for DeviceNet Safety No Supporting protocol for PROFIsafe No Supporting protocol for SafetyBUS p No External reset possible No