Wylex D25 10kA 3P MCB (3MW)
£42.06 Incl. VAT
Wylex NH Miniature Circuit Breaker is the thermal-magnetic current limiting type, having a compact construction which has been achieved by not only minimising the number of parts but also the number of welded joints and connections. Critical material selection ensures reliability and durability. Typical of this is the choice of silver graphite for the fixed contact. It has an easy to operate handle with a trip-free toggle mechanism – so even when the handle is held in the ‘on’ position the MCB is free to trip. The back-up protection is required only if the prospective short circuit current at the point of installation exceeds the breaking capacity of the MCB. When providing back-up protection consideration must be given to discrimination between the MCB and fuse.Wylex NH Miniature Circuit Breaker is the thermal-magnetic current limiting type, having a compact construction which has been achieved by not only minimising the number of parts but also the number of welded joints and connections. Critical material selection ensures reliability and durability. Typical of this is the choice of silver graphite for the fixed contact. It has an easy to operate handle with a trip-free toggle mechanism – so even when the handle is held in the ‘on’ position the MCB is free to trip. The back-up protection is required only if the prospective short circuit current at the point of installation exceeds the breaking capacity of the MCB. When providing back-up protection consideration must be given to discrimination between the MCB and fuse. · · · D curve trip characteristic (10-20In) · · 10kA to BS EN 60898-1 (15kA to BS EN 60947-2) @ 415V AC · · Triple pole MCB · · 10kA Fault Rating · · Energy limiting Class 3 · · Compliant with BS EN 60898 and EN 60947-2
Description
Technical Specifications Technical Specifications Miniature circuit breaker (MCB) Rated voltage 230 V Rated current 25 A Width in number of modular spacings 3 Rated impulse-withstand voltage (Uimp) 4 kV Rated short-circuit breaking capacity Icn EN 60898 at 400 V 10 kA Number of poles (total) 3 Rated short-circuit breaking capacity Icn EN 60898 at 230 V 10 kA Rated insulation voltage Ui 400 V Current limiting class 3 Number of protected poles 3 Over voltage category 3 Frequency 50 – 50 Hz Connectable conductor cross section multi-wired 0.75 – 25 mm² Ambient temperature during operating -5 – 40 °C Additional equipment possible No Flush-mounted installation No Concurrently switching N-neutral No