Schneider Electric TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 25A, 220 V DC coil

Schneider Electric TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 25A, 220 V DC coil

£161.33 Incl. VAT

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 25A, 220 V DC coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3, AC-4 – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – [Ie] rated operational current: 25 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – motor power kW: 11 kW at 380…400 V AC 50/60 Hz AC-3, 11 kW at 415…440 V AC 50/60 Hz AC-3, 15 kW at 500 V AC 50/60 Hz AC-3, 15 kW at 660…690 V AC 50/60 Hz AC-3, 5.5 kW at 220…230 V AC 50/60 Hz AC-3, 5.5 kW at 400 V AC 50/60 Hz AC-4 – motor power hp: 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 25 A at <= 60 °C for power circuit – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A <= 40 °C 1 min power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 240 A <= 40 °C 10 s power circuit, 380 A <= 40 °C 1 s power circuit, 50 A <= 40 °C 10 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at <= 690 V coordination type 2 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – electrical durability: 1.4 Mcycles 40 A AC-1 at Ue <= 440 V, 1.65 Mcycles 25 A AC-3 at Ue <= 440 V – power dissipation per pole: 1.25 W AC-3, 3.2 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : spring terminals 1 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end, control circuit : spring terminals 2 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end, power circuit : spring terminals 1 cable(s) 4 mm² – cable stiffness: flexible – without cable end, power circuit : spring terminals 2 cable(s) 4 mm² – cable stiffness: flexible – without cable end – operating time: 16…24 ms opening, 53.55…72.45 ms closing – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 30 Mcycles. · · · New modern look & feel of all machines · · Designed to meet the requirements of Electro domestic and HVAC applications · · With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries · · Maintenance guide via EcoStruxureTM Facility Expect

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: LC1D253MD Categories: , , Brand: Product Code: 2500876538

Description

Technical Specifications  Technical Specifications Power contactor, AC switching Rated operation power at AC-3, 400 V 11.00 kW Number of normally closed contacts as main contact 0.00 Number of auxiliary contacts as normally open contact 1.00 Number of main contacts as normally open contact 3.00 Rated operation current Ie at AC-4, 400 V 12.00 A Rated operation power at AC-4, 400 V 5.50 kW Rated operation current Ie at AC-3, 400 V 25.00 A Rated operation current Ie at AC-1, 400 V 40.00 A Rated operation power NEMA – kW Number of auxiliary contacts as normally closed contact 1.00 Rated control supply voltage at DC 220.00 – 220.00 V Rated control supply voltage at AC 50 Hz – – – V Modular version No Rated control supply voltage at AC 60 Hz – – – V · Technical Data Sheet – Click to Download