Schneider Electric Tesys GV2 Circuit Breakermagnetic 6.3A Screw Clamp Terminals

Schneider Electric Tesys GV2 Circuit Breakermagnetic 6.3A Screw Clamp Terminals

£94.85 Incl. VAT

TeSys GV2, Circuit breaker, magnetic, 6,3A, screw clamp terminals. range: TeSys – product name: TeSys GV2 – device short name: GV2L – device application: motor – network type: AC – utilisation category: AC-3 conforming to IEC 60947-4-1, category A conforming to IEC 60947-2 – breaking capacity: 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 – [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 – magnetic tripping current: 78 A. · · · TeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for 3-phase motor applications 2.2kW@400V. · · It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. · · Connection by screw clamp terminals. · · Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. · · To complete motor protection, use in association with a thermal overload relay LRD010 (to be ordered separately). · · Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). · · Rating: 6.4A

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: GV2L10 Category: Brand: Product Code: 2500045085

Description

Technical Specifications  Technical Specifications Motor protection circuit-breaker Width 45 mm Depth 97 mm Height 89 mm Number of poles 3 Rated permanent current Iu 6.3 A Rated operation power at AC-3, 400 V 2.2 kW Rated operation power at AC-3, 230 V 1.5 kW Rated short-circuit breaking capacity Icu at 400 V, AC 100 kA Overload release current setting – – – A Adjustment range undelayed short-circuit release 78 – 78 A Rated operating voltage 0 – 690 V With thermal overload protection No With integrated auxiliary switch No With integrated under voltage release No Phase failure sensitive Yes · Technical Data Sheet – Click to Download