Schneider Electric NG125, circuit breaker, NG125N, 3p, 63A, C curve

Schneider Electric NG125, circuit breaker, NG125N, 3p, 63A, C curve

£388.27 Incl. VAT

This Acti9 NG125N is a low voltage circuit breaker. It is a 3P circuit breaker with 3 protected poles, 63A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 25kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard and 25kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. It is suitable for isolation in the industrial sector according to IEC/EN 60947-2 standard. The fault tripping is indicated by a red mechanical state indicator light on the front face of the circuit breaker. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is equal or below 375VDC, 220VAC to 240VAC, 380VAC to 415VAC, 440VAC or 500VAC. The Ui rated insulation voltage is 690VAC. The Uimp rated impulse withstand voltage is 8kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 9 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 81mm x (H) 103mm x (D) 81mm. The weight is 0.72kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals in enclosure. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 70°C. · · · This Acti9 NG125N is a low voltage circuit breaker. · · It is a 3P circuit breaker with 3 protected poles, 63A rated current and C tripping curve. · · The rated short circuit breaking capacity goes up to 25kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard and 25kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard. · · It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. · · This miniature circuit breaker protects circuits against short circuit and overload current.

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal

Description

Technical Specifications  Technical Specifications Miniature circuit breaker (MCB) Rated impulse-withstand voltage (Uimp) 8.00 kV Rated insulation voltage Ui 690.00 V Number of protected poles 3.00 Current limiting class – Rated short-circuit breaking capacity Icn EN 60898 at 400 V – kA Recess depth 47.00 mm Number of poles (total) 3.00 Rated voltage 400.00 V Width in number of modular spacings 4.50 Rated current 63.00 A Rated short-circuit breaking capacity Icn EN 60898 at 230 V – kA Pollution degree 3.00 Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 25.00 kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 50.00 kA Over voltage category 4.00 Frequency 50.00 – 60.00 Hz Connectable conductor cross section solid-core 1.50 – 50.00 mm² Connectable conductor cross section multi-wired 1.00 – 35.00 mm² Ambient temperature during operating 30.00 – 70.00 °C Concurrently switching N-neutral No Additional equipment possible Yes · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2188502 · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2188503