Schneider Electric Basic analog input kit STB, 4..20mA, 2 I, 10 bits
£224.24 Incl. VAT
This product is part of the Modicon STB range, an offer of modular distributed I/O. This basic analogue input kit is an accessory kit of Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC). It has 2 analogue inputs (current 4mA to 20mA) with 10bit resolution. This product is compatible with most major fieldbus networks. It is an analogue input kit with a rated supply voltage of 24V DC and a current consumption of 30mA at 5V DC for logic bus. The response time is 5ms. It is an IP20 rated product. Its dimensions are 128.3mm (width) x 70mm (depth) x 13.9mm (height). It is suitable for packaging, bottling, assembly, distribution, textile, printing and semiconductor machines applications. This product is certified by FM Class 1 Division 2, ATEX category 3G, CE, UL, CSA and C-Tick. This kit is suitable for use with mounting base STBXBA1000 and power distribution module STBPDT3100/3105. The kit includes STBXTS1100, 6-terminal screw type connector, STBXBA1000 base, STBXTS2100, 6-terminal spring clamp connector and STBACI1225 module. The Modicon STB distributed I/O solution is an open, modular input/output system that makes it possible to design automation islands managed by a master controller via a bus or communication network. · · · This product is part of the Modicon STB range, an offer of modular distributed I/O. · · This basic analogue input kit is an accessory kit of Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC). · · It has 2 analogue inputs (current 4mA to 20mA) with 10bit resolution. · · This product is compatible with most major fieldbus networks. · · It is an analogue input kit with a rated supply voltage of 24V DC and a current consumption of 30mA at 5V DC for logic bus. The response time is 5ms.
Out of Stock
Description
Technical Specifications Technical Specifications Fieldbus, decentr. periphery – analogue I/O module Width 128.3 mm Height 13.9 mm Depth 70 mm Number of HW-interfaces industrial Ethernet 0 Number of HW-interfaces RS-232 0 Number of HW-interfaces RS-422 0 Number of analogue inputs 2 Number of analogue outputs 0 Number of HW-interfaces serial TTY 0 Number of HW-interfaces RS-485 0 Number of HW-interfaces other 0 Number of HW-interfaces parallel 0 Number of HW-interfaces PROFINET 0 Resolution of the analogue outputs – Bit Number of HW-interfaces Wireless 0 Resolution of the analogue inputs 10 Bit Number of HW-interfaces USB 0 Supply voltage AC 50 Hz – – – V Supply voltage AC 60 Hz – – – V Supply voltage DC 24 – 24 V Suitable for safety functions No Supporting protocol for ASI No Supporting protocol for INTERBUS No Supporting protocol for TCP/IP No Supporting protocol for CAN No Supporting protocol for PROFIBUS No Supporting protocol for LON No Input, resistance thermometer No Input, resistor No Input, voltage No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for Foundation Fieldbus No Supporting protocol for EtherNet/IP No Supporting protocol for SERCOS No Supporting protocol for PROFINET CBA No Supporting protocol for PROFINET IO No Supporting protocol for KNX No Supporting protocol for MODBUS No Supporting protocol for DeviceNet No Supporting protocol for Data-Highway No Supporting protocol for SUCONET No Output, voltage No Output, current No Input, current Yes Input, thermocouple No Radio standard GPRS No Radio standard WLAN 802.11 No Radio standard Bluetooth No Supporting protocol for other bus systems No Supporting protocol for SafetyBUS p No Supporting protocol for PROFIsafe No Supporting protocol for INTERBUS-Safety No Supporting protocol for DeviceNet Safety No Radio standard UMTS No Radio standard GSM No IO link master No Output signal configurable No Analogue outputs configurable No Appendant operation agent (Ex ia) No Front built-in possible No Wall mounting/direct mounting No System accessory Yes Appendant operation agent (Ex ib) No Rail mounting possible Yes Analogue inputs configurable Yes Input signal, configurable Yes Fieldbus connection over separate bus coupler possible Yes Rack-assembly possible Yes · Technical Data Sheet – Click to Download





