Schneider Electric Acti9 Smartlink – Modbus RS485 slave – smart communication I/O module
£509.46 Incl. VAT
This Acti 9 SmartLink Modbus Slave is a smart communication module with 11 channels. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It needs to be associated to a Master SmartLink SI B thanks to the Modbus RS485 connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It is supplied with 1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Modbus, RTU, RS485 serial connection. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 99. It is a 4-pin connector type of bus. It is a plug-in connection. The maximum length of the bus is 1000m. The maximum cable length is 500m. The voltage power supply is 24VDC +/- 10%. The Maximum input current is 1,5A. The Maximum inrush current is 3A. The degree of protection is IP20. The pollution degree is 3. It complies with RoHS directive. The duration of saving memory is 10 years. The dimensions are (W) 359mm x (H) 23mm x (D) 42mm. The weigth is 195g. The operating temperature is -25°C to + 60°C and only +50°C if vertical mouting. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 61131-2 standard. · · · Acti 9 smartlink communication module/modbus · · Allows up to 11 wired devices · · 1 group of 11 channels · · BMS controller compatible · · Reset button on front face · · LED local signalling
Out of Stock
Description
Technical Specifications Technical Specifications Fieldbus, decentr. periphery – analogue/digital I/O module Width 359 mm Depth 42 mm Height 23 mm Number of HW-interfaces USB 0 Resolution of the analogue outputs – Bit Resolution of the analogue inputs – Bit Output current at digital output 0.1 A Number of HW-interfaces Wireless 0 Number of HW-interfaces PROFINET 0 Number of HW-interfaces RS-485 1 Input current at signal 1 2.5 mA Number of HW-interfaces industrial Ethernet 0 Number of digital outputs 11 Number of digital inputs 22 Number of analogue inputs 0 Number of analogue outputs 0 Number of HW-interfaces RS-422 0 Number of HW-interfaces RS-232 0 Number of HW-interfaces serial TTY 0 Number of HW-interfaces other 0 Number of HW-interfaces parallel 0 Time delay at signal change – – – ms Output voltage at digital output 24 – 24 V Supply voltage AC 50 Hz – – – V Supply voltage AC 60 Hz – – – V Permitted voltage at input 19.2 – 28.8 V Supply voltage DC 24 – 24 V Analogue inputs configurable Yes Analogue outputs configurable No Digital outputs configurable Yes Fieldbus connection over separate bus coupler possible No Wall mounting/direct mounting Yes Front built-in possible No Appendant operation agent (Ex ia) No Rack-assembly possible No Rail mounting possible No System accessory Yes Analogue output signal configurable No Digital inputs configurable Yes Appendant operation agent (Ex ib) No Radio standard GPRS No Analogue output, voltage No Analogue output, current No Analogue input signal configurable No Analogue input, thermocouple No Analogue input, resistor temperature No Analogue input, resistor No Analogue input, voltage No Analogue input, current No Radio standard GSM No Radio standard UMTS No IO link master No Short-circuit protection, digital outputs available Yes Radio standard Bluetooth No Radio standard WLAN 802.11 No Supporting protocol for EtherNet/IP No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for DeviceNet Safety No Supporting protocol for INTERBUS-Safety No Supporting protocol for PROFIsafe No Supporting protocol for SafetyBUS p No Supporting protocol for other bus systems No Supporting protocol for MODBUS Yes Supporting protocol for PROFINET IO No Supporting protocol for LON No Supporting protocol for PROFINET CBA No Supporting protocol for SERCOS No Supporting protocol for Foundation Fieldbus No Supporting protocol for CAN No Supporting protocol for INTERBUS No Supporting protocol for KNX No Supporting protocol for ASI No Supporting protocol for Data-Highway No Supporting protocol for DeviceNet No Supporting protocol for SUCONET No Supporting protocol for PROFIBUS No Supporting protocol for TCP/IP No With optical interface No Suitable for safety functions No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2192424 · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2224944





