This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with 80A In rated current, 30mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C. · · · This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). · · It is a 4P circuit breaker with 80A In rated current, 30mA earth leakage sensitivity and AC type protection class. · · This product protects against electrical shock by direct or indirect contact and fire hazards. · · It performs the function of disconnection of electrical circuits in case of earth fault. · · Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. · · This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance · · This product is compliant with EN/IEC 61008-1 standard. · · The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. · · It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ue operational voltage is 380VAC to 415VAC.

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9R11480 Category: Brand: Product Code: 2500867042

Description

Technical Specifications  Technical Specifications Residual current circuit breaker (RCCB) Rated current 80 A Rated voltage 415 V Recess depth 73.5 mm Number of poles 4 Pollution degree 3 Width in number of modular spacings 4 Rated impulse-withstand voltage (Uimp) 6 kV Rated insulation voltage Ui 500 V Rated fault current 30 A Surge current capacity 0.25 kA Short-circuit breaking capacity (Icw) 10 kA Connectable conductor cross section multi-wired 1 – 25 mm² Connectable conductor cross section solid-core 1 – 35 mm² Ambient temperature during operating -5 – 60 °C Selective protection No Additional equipment possible Yes With interlocking device No Short-time delayed tripping No · Technical Data Sheet – Click to Download