Schneider Electric Merl Acti9 Vigi Vigi Ic60 Rcd 4P 25A
£253.98 Incl. VAT
This Acti9 Vigi iC60 is a modular add-on residual current devices. It is a 4P, rated current is 25A, operating voltage is 400VAC to 415VAC according to IEC 61009-1. The earth leakage protection class is A type with a sensitivity of 30mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of persons and protection of installations. This product is compliant with EN 61009-1 and IEC 61009-1 standard. The Ue rated operational voltage is 400VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 6. The dimensions are (W) 54mm x (H) 91mm x (D) 73.5mm. The weight is 0.245kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature -25°C to +60°C. The storage temperature is -40°C to +85°C. · · · This Acti9 Vigi iC60 is a modular add-on residual current devices. · · It is a 4P, rated current is 25A, operating voltage is 400VAC to 415VAC according to IEC 61009-1. · · The earth leakage protection class is A type with a sensitivity of 30mA and a voltage independent technology. · · This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. · · A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. · · It can be combined with iC60 or Acti 9 Reflex iC60, to provide protection of persons and protection of installations. · · This product is compliant with EN 61009-1 and IEC 61009-1 standard. · · The Ue rated operational voltage is 400VAC. · · The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV.
Out of Stock
Description
Technical Specifications Technical Specifications Residual current circuit breaker (RCCB) module Nominal current 25 A Number of poles 4 Pollution degree 3 Surge current capacity 0.25 kA Max. delay time 0 ms Rated impulse-withstand voltage (Uimp) 6 kV Rated insulation voltage Ui 500 V Nominal voltage 400 – 415 V Connectable conductor cross section solid-core 1 – 25 mm² Rated fault current 0.03 – 0.03 A Connectable conductor cross section multi-wired 1 – 16 mm² Ambient temperature during operating 25 – 60 °C Anti-nuisance tripping version No With interlocking device No Delay adjustable No Rated fault current adjustable No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2190551