Schneider Electric Surge Arrester IPrdr 20 Triple Pole+Neutral Remote Transfer 20Ka 350V
£619.61 Incl. VAT
This Acti9 iPRD20r surge arrester protects 3P+N installations. it allows quick replacement of damaged cartridges. This Type 2 device is recommended for medium risk level and incoming panel board. It offers remote reporting of the -cartridge must be changed- message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Imax rated discharge current is up to 40kA. The In nominal discharge current is 15kA. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in common mode (between neutral and earth) is 260VAC. The Up maximum voltage protection level is 1.4kV in common mode and 1.2kV in differential mode. The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard. · · · Type 2 Surge Arrester · · VisiTrip™: quickly detects the defects of protection against the surges and reduces intervention time · · Certified back-up protection coordination with disconnecting circuit-breakers · · End of life indication on the device · · IP65 Enclosure · · The Imax rated discharge current is up to 40kA. The In nominal discharge current is 15kA. · · The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. · · The Uc maximum continuous operating voltage in CM common mode (between neutral and earth) is 260VAC. · · The Up Voltage protection level in CM common mode and in DM differential mode is below 1.4kV. · · The Up Voltage protection level in CM common mode (between phase and neutral) is 1.2kV.
Out of Stock
Description
Technical Specifications Technical Specifications Surge protection device for power supply systems Nominal voltage DC – V Max. voltage (Uc) 350 V Number of conductors (without earthing) 3 Nominal voltage AC 400 V Voltage protection level L-N 1.1 kV Max. continuous voltage DC – V Max. PV-voltage – V Max. conductor cross section flexible (fine-strand) 16 mm² Voltage protection level 1.4 kV Voltage protection level N-PE 1.4 kV Max. conductor cross section solid (solid, stranded) 25 mm² Max. discharge surge current (8/20) 20 kA Nominal discharge surge current 8/20 µs (In) 5 kA Short-circuit breaking capacity (Isccr) – kA With remote signalling contact Yes System configuration TN-C No System configuration TN-S Yes System configuration IT No System configuration TN No Integrated backup fuse No System configuration DC No Type / Test class 2 Yes System configuration TT Yes System configuration other No System configuration TN-C-S No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2224955