Schneider Electric Vigi C120, earth leakage add-on block, 4p, 300mA, class A si
£507.70 Incl. VAT
This Acti9 Vigi C120 is a modular add-on residual current devices. It has 4P with 4 protected poles, rated current is 125A and operating voltage is 230VAC to 415VAC. The earth leakage protection class is A-SI type with a sensitivity of 300mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. The A-SI type provides increased immunity from electrical interference and polluted or corrosive environments. This product is compliant with EN 61009 standard. Electrical endurance goes up to 20000 cycles. The Ue rated operational voltage is from 230VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on 35 mm symmetrical DIN rail. The width in 9mm pitches is 10. The product color is white (RAL9003). The dimensions are (W) 198mm x (H) 95mm x (D) 73mm. The weight is 0.58kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 60°C. · · · This Acti9 Vigi C120 is a modular add-on residual current devices. · · It has 4P with 4 protected poles, rated current is 125A and operating voltage is 230VAC to 415VAC. · · The earth leakage protection class is A-SI type with a sensitivity of 300mA and a voltage independent technology. · · This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. · · The A-SI type provides increased immunity from electrical interference and polluted or corrosive environments.
Out of Stock
Description
Technical Specifications Technical Specifications Residual current circuit breaker (RCCB) module Nominal current 125 A Number of poles 4 Rated insulation voltage Ui 500 V Surge current capacity 3 kA Max. delay time 0 ms Pollution degree 3 Rated impulse-withstand voltage (Uimp) 6 kV Nominal voltage 230 – 415 V Connectable conductor cross section solid-core 1 – 50 mm² Rated fault current 0.3 – 0.3 A Connectable conductor cross section multi-wired 1 – 35 mm² With interlocking device No Ambient temperature during operating -25 – 60 °C Delay adjustable No Rated fault current adjustable No Anti-nuisance tripping version Yes · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2188496