Schneider Electric TeSys D contactor, 4p(4 NO), AC-1, <= 440 V 125A, 24 V AC 50/60 Hz coi
£500.09 Incl. VAT
TeSys D contactor, 4p(4 NO), AC-1, <= 440 V 125A, 24 V AC 50/60 Hz coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: resistive load – utilisation category: AC-1 – poles description: 4P – pole contact composition: 4 NO – [Ue] rated operational voltage: <= 300 V DC 25…400 Hz for power circuit, <= 690 V AC for power circuit – overvoltage category: III – [Icw] rated short-time withstand current: 135 A <= 40 °C 10 min power circuit, 320 A <= 40 °C 1 min power circuit, 640 A <= 40 °C 10 s power circuit, 990 A <= 40 °C 1 s power circuit – associated fuse rating: 160 A gG at <= 690 V coordination type 2 for power circuit, 200 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 1000 V for power circuit conforming to IEC 60947-4-1, 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL – protective cover: without – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : screw clamp terminals 1 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, power circuit : connector 1 cable(s) 4…50 mm² – cable stiffness: flexible – with cable end, power circuit : connector 1 cable(s) 4…50 mm² – cable stiffness: flexible – without cable end, power circuit : connector 1 cable(s) 4…50 mm² – cable stiffness: solid – without cable end, power circuit : connector 2 cable(s) 4…16 mm² – cable stiffness: flexible – with cable end, power circuit : connector 2 cable(s) 4…25 mm² – cable stiffness: flexible – without cable end, power circuit : connector 2 cable(s) 4…25 mm² – cable stiffness: solid – without cable end – tightening torque: control circuit : 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm, control circuit : 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2, power circuit : 9 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm, power circuit : 9 N.m – on connector hexagonal 4 mm – operating time: 20…35 ms closing, 6…20 ms opening – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 4 Mcycles. · · · TeSys D contactor, 4-pole (4NO), for non-inductive load applications up to 125A/1000V AC-1. · · It provides a 24V 50/60Hz AC coil, power connection by screw terminals, control connection by screw clamp terminals. · · For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. · · Compact (96mm width), DIN-rail mounting or screw fixing.
Out of Stock
Description
Technical Specifications Technical Specifications Power contactor, AC switching Number of normally closed contacts as main contact 0.00 Rated operation power at AC-3, 400 V – kW Number of auxiliary contacts as normally open contact 0.00 Rated operation current Ie at AC-4, 400 V – A Rated operation power NEMA – kW Number of main contacts as normally open contact 4.00 Rated operation power at AC-4, 400 V – kW Rated operation current Ie at AC-1, 400 V 125.00 A Rated operation current Ie at AC-3, 400 V – A Number of auxiliary contacts as normally closed contact 0.00 Rated control supply voltage at AC 60 Hz 24.00 – 24.00 V Modular version No Rated control supply voltage at DC – – – V Rated control supply voltage at AC 50 Hz 24.00 – 24.00 V · Technical Data Sheet – Click to Download