Apollo Fire Detectors

  • Placeholder

    Apollo XP95 Open Area Multi Tone Sounder Outdoor Red Body

    £186.77 Incl. VAT

    In Stock for Delivery

    The XP95 Open-Area Multi-Tone Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. · · · Updated to include choice of tones: Apollo, slow whoop and DIN · · Two volume settings 92dB(A) and 100dB(A) · · Synchronisation of tones · · Individual and group addressing · · Loop Powered · · IP66 rated

  • Placeholder

    Apollo XP95 Loop Powered 100/92Db Sounder Red

    £91.97 Incl. VAT

    In Stock for Delivery

    Apollo XP95 Multi-Tone Open-Area Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. The multi-tone open-area alarm device is powered directly from the loop and need no external power supply. It operates at 18 to 28VDC and is polarity sensitive. Synchronisation of the tones ensures the integrity of the signal – tones from different sounders do not merge into one signal that could be mistaken for a different tone. A nominal sound output of 100dBA is achieved at a current consumption of 5mA in the case of the sounder and 9mA for the sounder beacon. Many control panels will be able to drive up to 20 sounders per loop on average. The device will operates only with control equipment using the Apollo XP95 or Discovery protocol. The features of the multi-tone open-rea alarm device is available only when the sounder is connected to a control panel with the appropriate software. The multi-tone open-area sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. · · · Updated to include choice of tones: Apollo, slow whoop and DIN · · Synchronisation of tones · · Individual and group addressing · · Loop powered · · IP21C Degree of protection · · Power-up surge current 1.2mA

  • Placeholder

    Apollo Detector Heat Br Rate Of Rise Series 65

    £18.19 Incl. VAT

    In Stock for Delivery

    Apollo 55000-127APO Series 65 BR Heat Detector 75c, The Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions. · · · Can be used for applications where smoke detectors are unsuitable · · Ideal for environments that are dirty or smoky under natural conditions · · Wide operating voltage · · Flashing LED and magnet operated test switch option · · Wide voltage range (9V to 33V DC) · · 3 year warranty

  • Placeholder

    Apollo Removal Alert Base For Alarmsense Detectors

    £5.48 Incl. VAT

    In Stock for Delivery

    Apollo 45681-244APO AlarmSense Base, The base is used for installing detectors that do not require an integral sounder or sounder visual indicator. · · · Quick and simple installation compliant with BS 5839 · · Detects the removal of a detector head and · · reports a fault · · Continues to work during unauthorised removal · · of detectors · · Quick and simple installation

  • Placeholder

    Apollo Fire Detect XP95 Locking White Cap 45681-278

    £4.25 Incl. VAT

    In Stock for Delivery

    A white circular plastic housing body designed to act as a locking base for XP95 fire detectors. · · · Locking Cap · · White · · XP95 Range · · For use with the flowing intelligent sounder bases: · · 45681-702 / 45681-393 / 45681-330 / 45681-332 / 45681-333 / 45681-276 / 45681-277 / 45681-290 / 45681-300 · · Sleek and stylish white design to complement any décor

  • Placeholder

    Apollo Locking Cap Red for XP95 Sounders/Bases/Beacons

    £3.61 Incl. VAT

    In Stock for Delivery

    · · Locking Cap · · Red · · XP95 Range · · For use with the flowing intelligent sounder bases: · · 45681-702 / 45681-393 / 45681-330 / 45681-332 / 45681-333 / 45681-276 / 45681-277 / 45681-290 / 45681-300 · · Durable plastic construction

  • Placeholder

    Apollo Sounder Multitone Indicator Open Area IP65 Red For XP95

    £223.66 Incl. VAT

    Out of Stock

    Apollo 55000-298APO Weatherproof MultiTone Open Area Sounder Visual Indicator with Isolator Red XP95, Apollo XP95 Weatherproof Multi-Tone Open-Area Sounder Visual Indicator is designed for use in outdoor open areas and can be connected to any Discovery or XP95 system. The sounder visual indicator complements Apollo’s intelligent and integrated base sounders as well as the multi-tone open-area sounder. The multi-tone open-area alarm devices are powered directly from the loop and need no external power supply. It operates at 18 to 28VDC and are polarity sensitive. Synchronisation of the tones ensures the integrity of the signal – tones from different sounders do not merge into one signal that could be mistaken for a different tone. A nominal sound output of 100dBA is achieved at a current consumption of 5mA in the case of the sounder and 9mA for the sounder beacon. The maximum number of sounders that may be connected to a particular loop should · · · IP66 · · Synchronisation of alert and evacuate tones · · Individual and group addressing · · Built in isolator · · Operate at 18 to 28VDC and polarity sensitive · · so that the functional options of the sounder are identical with those of the sounder control unit. The multi-tone open-area alarm devices are fitted to the mounting surface with four screws. The weatherproof versions have an additional square backbox and · · Synchronisation of alert and evacuate tones · · Individual and group addressing · · Built in isolator · · Operate at 18 to 28VDC and polarity sensitive

  • Placeholder

    Apollo Alarmsense High Temp Heat Detector

    £17.20 Incl. VAT

    In Stock for Delivery

    Apollo 55000-193APO AlarmSense CS Heat Detector / Alarm , Apollo AlarmSense CS Heat Detector is designed to suit a wide variety of operating conditions. It is made of polycarbonate and available in white. A static heat detector (CS) which responds only when a fixed temperature has been reached and a rate-of-rise detector (A1R) which has a fixed upper limit · · · but in addition · · measures the rate of increase in temperature. AlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires · · making installation quicker and less expensive. AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system t · · AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products · · such as beacons · · to help meet the requirements of the Disability Discrimination Act (DDA). · · Can be used for applications where smoke detectors are unsuitable · · Ideal environments that are dirty or smoky under normal conditions · · CS detectors are ideal for use in environments with rapid temperature fluctuations · · 360C visibility of LEDs

  • Placeholder

    Apollo Series 60 & 65 Range Of Base Diode

    £3.88 Incl. VAT

    In Stock for Delivery

    Diode base designed for use with conventional systems that have manual call points and detector bases on the same circuit. Series 65 incorporates well-proven sensing technologies, including an Integrated Circuit based on that used in XP95 analogue addressable detectors. The Series 65 range has a wide operating voltage of 9 to 33V and consists of ionisation, integrating ionisation and optical smoke detectors, four grades of heat detector and a range of bases. · · · Base is fitted with a Schottky diode on the “L1 IN” and “L1 OUT” wiring terminals · · Base can only be used with compatible control equipment · · Detector locking mechanism · · One way fit and easy to wire · · Contains an earth connector · · Continues to work during unauthorised removal of detectors

  • Placeholder

    Apollo Savwire Base For Series 60/65 Detectors

    £13.73 Incl. VAT

    In Stock for Delivery

    Designed to allow Series 65 detectors to be used in ‘Sav-Wire’ detection and alarm systems and can only be used in conjunction with a Sav-Wire compatible control panel. The base incorporates a circuit which detects the removal of a detector head. If a detector is removed from the base, the control panel will give a fault signal. · · · Detector locking mechanism · · One-way fit · · Easy to wire · · Contains an earth connector · · 10 year Warranty · · Easy to install and use

  • Placeholder

    Apollo Detector Heat A1R Rate Of Rise Alarmsense

    £14.89 Incl. VAT

    In Stock for Delivery

    Apollo 55000-190APO AlarmSense A1R Heat Alarm / Detector, There are two heat detectors in the AlarmSense range designed to suit a wide variety of operating conditions. A static heat detector (CS) which responds only when a fixed temperature has been reached and a rate-of-rise detector (A1R) which has a fixed upper limit, but in addition, measures the rate of increase in temperature. · · · Can be used for applications where smoke detectors are unsuitable · · Ideal environments that are dirty or smoky under normal conditions · · CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms · · 360C visibility of LEDs · · Reduction of false alarms · · Quick and simple installation compliant with BS 5839 · · Applications B&Bs/guest houses Care homes Dusty environments HMOs Small to medium buildings University campuses · · Sends a cancel signal to stop all other alarms sounding · · compliant with BS 5839 · · Applications B&Bs/guest houses Care homes Dusty environments HMOs Small to medium buildings University campuses

  • Placeholder

    Apollo Beacon Base Isolated

    £46.43 Incl. VAT

    In Stock for Delivery

    Apollo Visual Indicator Base is a loop-powered visual indicator combined with a standard Intelligent mounting base. It is used to signal a fire alarm in enclosed areas. It can be used with either a detector fitted or with a cap as a stand-alone alarm device. The base is loop powered and normally pulled by its individual address. It is supplied with a built-in isolator. It responds to its own individual address set with a DIL switch, it also responds to a group address, set by means of a four segment DIL-switch and to a synchronisation address which is embedded in the unit. Addresses 1 to 111 are used exclusively for individual addresses, addresses 112 to 126 may be used as individual addresses but only if the four segment DIL-switch is not used, that is group addressing is disabled. If the four segment DIL-switch were set to any number other than the default 127, a pre-set analogue value of four would be transmitted to indicate a fault. It is recommended that the synchronisations address 0 is set by the control panel at regular intervals to align the internal clock to all visual indicator bases. The result is that the visual indicator bases are synchronised with each other when activated. It is made of white flame-retardant polycarbonate and translucent flame-retardant polycarbonate diffuser. · · · Once per second flash rate (red) · · Synchronisation of visual indicator flash · · Individual and group addressing · · Unique self-test feature · · Loop-powered · · Flash rate 1Hz