Industrial MCBs

  • Memshield 3 MCB 1-Pole 20A Type C 110/15kA - 18 x 80 x 75mm

    Memshield 3 MCB 1-Pole 20A Type C 110/15kA – 18 x 80 x 75mm

    £17.57 Incl. VAT

    In Stock for Delivery

    C Type MCB Suitable for Memsheild EBM Distribution Board · · · Can be used in MEMShield distribution boards · · 10kA to IEC 60898 · · 15kA to IEC 60947-2

  • Eaton Memshield 3 3-Pole 6A MCB Type C 10/15kA 54 x 80 x 75mm

    Eaton Memshield 3 3-Pole 6A MCB Type C 10/15kA 54 x 80 x 75mm

    £77.88 Incl. VAT

    In Stock for Delivery

    The Eaton MCBs are fitted with box clamp terminals suitable for use with cables up to 25mm² and have a unique box clamp barrier to prevent incorrect cable insertion. This 10/15kA MCB are designed & tested in accordance with IEC 60898 & IEC 60947-2. It is certified by KEMA. Type C MCBs are most commonly used in commercial and general applications where there are lighting or motor loads involving high switching surges that may cause unwanted operation of type B devices. Suitable for 230/400 VAC systems and are calibrated for use at 40°C. · · · DIN rail mountable · · Suitable for use with both pin and comb type busbar systems · · Suites RCBOs, RCCBs and isolators · · Positive contact is flag indicator · · Operating temperature: -25 to 55 °C · · Impulse withstand voltage: 5kV · · Energy limiting class 3

  • Eaton EMCH132 Memshield 3 MCB 1 Pole 32A Type C 110/15kA 18 x 80 x 75mm

    Eaton EMCH132 Memshield 3 MCB 1 Pole 32A Type C 110/15kA 18 x 80 x 75mm

    £17.57 Incl. VAT

    In Stock for Delivery

    EMCH132 is a Miniature circuit breaker with dual rated, 10kA to IEC 60898 and 15kA to IEC 60947-2. · · · Can be used in MEMShield distribution boards · · Din rail mounted

  • Eaton EMCH316 Memshield 3 3-Pole 16A MCB Type C 10/15kA 54 x 80 x 75mm

    Eaton EMCH316 Memshield 3 3-Pole 16A MCB Type C 10/15kA 54 x 80 x 75mm

    £74.62 Incl. VAT

    In Stock for Delivery

    The Eaton MCBs are fitted with box clamp terminals suitable for use with cables up to 25mm² and have a unique box clamp barrier to prevent incorrect cable insertion. This 10/15kA MCB are designed & tested in accordance with IEC 60898 & IEC 60947-2. It is certified by KEMA. Type C MCBs are most commonly used in commercial and general applications where there are lighting or motor loads involving high switching surges that may cause unwanted operation of type B devices. Suitable for 230/400 VAC systems and are calibrated for use at 40°C. · · · DIN rail mountable · · Suitable for use with both pin and comb type busbar systems · · Suites RCBOs, RCCBs and isolators · · Positive contact is flag indicator · · Operating temperature: -25 to 55 °C · · Impulse withstand voltage: 5kV · · Energy limiting class 3

  • Lewden E10-1C06 MCB 6A, C Type, 1 Pole, 10kA

    Lewden E10-1C06 MCB 6A, C Type, 1 Pole, 10kA

    £10.51 Incl. VAT

    In Stock for Delivery

    10kA Miniature Circuit Breaker protects against overload, short circuit and infrequent switching of circuits under normal conditions. For use in Lewden 3 phase boards. · · · 6A · · Single pole · · C Curve · · EN60898-1 · · Compliant to IEC /BS EN60898-1 IEC60947-2 · · Din rail mounted

  • Lewden EMS-1254P Main Switch Disconnector 125A 4 Pole

    Lewden EMS-1254P Main Switch Disconnector 125A 4 Pole

    £37.20 Incl. VAT

    Out of Stock

    Switch disconnector for the control of opening and closing of circuits under load. For use in Lewden 3 phase boards. · · · 125A · · 4 Pole · · 230/400V Rated Voltage · · 50mm² maximum cable capacity · · Category of duty: AC22B · · Operating cycles: 10,000 · · Operating Temperature: -5° to 40°C · · Max Torque: 3Nm · · IP Rating: IP20 · · EN609-471-1 / EN60947-3 compliant

  • Lewden E10-3C16 MCB 16A, C Type, 3 Pole, 10kA

    Lewden E10-3C16 MCB 16A, C Type, 3 Pole, 10kA

    £31.84 Incl. VAT

    In Stock for Delivery

    10kA Miniature Circuit Breaker protects against overload, short circuit and infrequent switching of circuits under normal conditions. For use in Lewden 3 phase boards. · · · 16A · · Triple Pole · · C Curve · · EN60898-1 · · Compliant to IEC /BS EN60898-1 IEC60947-2 · · Din rail mounted

  • Lewden MCB (E10-3C25) 25A C Type 3 Pole 10kA

    Lewden MCB (E10-3C25) 25A C Type 3 Pole 10kA

    £31.84 Incl. VAT

    In Stock for Delivery

    10kA Miniature Circuit Breaker protects against overload, short circuit and infrequent switching of circuits under normal conditions. For use in Lewden 3 phase boards. · · · 25A · · Triple Pole · · C Curve · · EN60898-1 · · Compliant to IEC /BS EN60898-1 IEC60947-2 · · Din rail mounted

  • Lewden MCB (E10-3C06) 6A - C Type - 3 Pole - 10kA

    Lewden MCB (E10-3C06) 6A – C Type – 3 Pole – 10kA

    £31.84 Incl. VAT

    In Stock for Delivery

    10kA Miniature Circuit Breaker protects against overload, short circuit and infrequent switching of circuits under normal conditions. For use in Lewden 3 phase boards. · · · 6A · · Triple Pole · · C Curve · · EN60898-1 · · Compliant to IEC /BS EN60898-1 IEC60947-2 · · Din rail mounted

  • Lewden E10-1C40 MCB 40A, C Type, 1 Pole 10kA

    Lewden E10-1C40 MCB 40A, C Type, 1 Pole 10kA

    £10.51 Incl. VAT

    In Stock for Delivery

    10kA Miniature Circuit Breaker protects against overload, short circuit and infrequent switching of circuits under normal conditions. For use in Lewden 3 phase boards. · · · 40A · · Single pole · · C Curve · · EN60898-1 · · Compliant to IEC /BS EN60898-1 IEC60947-2 · · Din rail mounted

  • Lewden MCB (E10-1C16) 16A, C Type, 1 Pole 10kA

    Lewden MCB (E10-1C16) 16A, C Type, 1 Pole 10kA

    £10.51 Incl. VAT

    In Stock for Delivery

    10kA Miniature Circuit Breaker protects against overload, short circuit and infrequent switching of circuits under normal conditions. For use in Lewden 3 phase boards. · · · 16A · · Single pole · · C Curve · · EN60898-1 · · Compliant to IEC /BS EN60898-1 IEC60947-2 · · Din rail mounted

  • Lewden MCB (E10-1D20) 20A, D Type, 1 Pole, 10kA

    Lewden MCB (E10-1D20) 20A, D Type, 1 Pole, 10kA

    £27.16 Incl. VAT

    Out of Stock

    10kA Miniature Circuit Breaker protects against overload, short circuit and infrequent switching of circuits under normal conditions. For use in Lewden 3 phase boards. · · · 20A · · Single pole · · D Curve · · EN60898-1 · · Compliant to IEC /BS EN60898-1 IEC60947-2 · · Din rail mounted