Apollo Fire Detectors Intelligent Input/Output Unit Twin

Brand: Apollo Fire DetectorsProduct code: SA4700-104APOGo Magpie Ref: 5060062360595

The Intelligent Twin Input/Output Unit provides the function of two Input/Output Units within one enclosure. The two units are electrically independent of each other. There is a DIL switch on each unit to set the address. Both input/output units in the enclosure provide supervision of one or more normally open volt free contacts connected to a single pair of cables and a set of changeover relay output contacts. The Intelligent Twin Input/Output Unit is available in the new faceplate style enclosure. This can be mounted with the supplied backbox for surface mounting or flush mounted using a UK double gang, flush mounting back-box of minimum depth 30mm. · · · Improved design for ease of wiring meaning faster installation · · Contains controllable isolator · · Address range 1 to 254 · · Nine pre-configured modes, including compatibility mode from XP95/Discovery to core protocol systems · · Failsafe mode (meets BS 7273-4 requirements) · · Configurable input styles · · Earth fault monitoring · · Protocol Voltage 5 to 13V peak to peak · · Quiescent Current Tested At 24V dc · · Operating Temperature -40 to 70C

£80.30inc VAT£66.92 ex VAT
In stock
UK deliveryStandard shipping is £2.99 inc VAT on eligible orders. Final delivery options are confirmed at checkout.
Quantity
1
✓ Secure checkout✓ UK customer support✓ Trusted suppliers
PRODUCT INFORMATION

Description

The Intelligent Twin Input/Output Unit provides the function of two Input/Output Units within one enclosure. The two units are electrically independent of each other. There is a DIL switch on each unit to set the address. Both input/output units in the enclosure provide supervision of one or more normally open volt free contacts connected to a single pair of cables and a set of changeover relay output contacts. The Intelligent Twin Input/Output Unit is available in the new faceplate style enclosure. This can be mounted with the supplied backbox for surface mounting or flush mounted using a UK double gang, flush mounting back-box of minimum depth 30mm. · · · Improved design for ease of wiring meaning faster installation · · Contains controllable isolator · · Address range 1 to 254 · · Nine pre-configured modes, including compatibility mode from XP95/Discovery to core protocol systems · · Failsafe mode (meets BS 7273-4 requirements) · · Configurable input styles · · Earth fault monitoring · · Protocol Voltage 5 to 13V peak to peak · · Quiescent Current Tested At 24V dc · · Operating Temperature -40 to 70C

£80.30inc VAT
Quantity
1