High Power Contactor TeSys Giga 3 pole (3NO), AC-3=440V 225A, standard version, 100…250V wide band AC/DC coil
£839.88 Incl. VAT
TeSys Giga contactors, Contactors to control motors up to 800 A (450 kW / 400V) or switch power up to 1050A. TeSys Giga is the range of high current contactors from 115 A to 800 A for AC-3 (motor) applications and from 250 A to 1050 A for AC-1 (resistive) applications. · · · TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 225A 132kW at 440V. · · It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). · · Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. · · It procures high reliability and durability with 5 Mcycles mechanical durability. · · Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. · · It is possibility to replace switching module (main contacts), enhancement contactor life. · · Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. · · To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. · · It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. · · It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude.
Out of stock
Description
Technical Specifications Technical Specifications Power contactor, AC switching Voltage type for actuating AC/DC Type of electrical connection of main circuit Bolt connection Rated operation power NEMA 150 kW Rated operation power at AC-4, 400 V 110 kW Rated operation current Ie at AC-4, 400 V 225 A Rated operation current Ie at AC-1, 400 V 330 A Rated operation current Ie at AC-3, 400 V 225 A Rated operation power at AC-3, 400 V 110 kW Number of main contacts as normally open contact 3 Number of normally closed contacts as main contact 0 Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as normally closed contact 1 Rated control supply voltage at AC 60 Hz 100 – 250 V Rated control supply voltage at AC 50 Hz 100 – 250 V Rated control supply voltage at DC 100 – 250 V Modular version No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2194119