Iprd20 Modular Surge Arrester 3 Pole + Neutral 350V

Iprd20 Modular Surge Arrester 3 Pole + Neutral 350V

£615.72 Incl. VAT

This Acti9 iPRD20 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for medium risk level and incoming panel board. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD20 is compatible with TT and TN-S earthing system. The Imax rated discharge current is 20kA. The In nominal discharge current is 5kA. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Up Voltage protection level in differential mode (between phase and neutral) is 1.1kV. The Up Voltage protection level in common mode (between neutral and earth) is 1.4kV. The Ue operating voltage is 230VAC or 400VAC +/- 10%. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard. · · · This Acti9 iPRD20 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. · · The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. · · It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. · · The associated circuit breaker Isc breaking capacity can go up to 50kA. · · This Acti 9 iPRD20 is compatible with TT and TN-S earthing system. · · The Imax rated discharge current is 20kA. The In nominal discharge current is 5kA. · · The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. · · The Uc maximum continuous operating voltage in CM common mode (between neutral and earth) is 260VAC. · · The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. · · The Up Voltage protection level in CM common mode and in DM differential mode is below 1.4kV.

12 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9L20600 Categories: , Brand: Part Number: 2500866972

Description

Technical Specifications  Technical Specifications Surge protection device for power supply systems Nominal discharge surge current 8/20 µs (In) 5 kA Nominal voltage AC 400 V Voltage protection level 1.1 kV Max. voltage (Uc) 350 V Number of conductors (without earthing) 3 Nominal voltage DC – V Max. continuous voltage DC – V Max. conductor cross section solid (solid, stranded) 35 mm² Max. conductor cross section flexible (fine-strand) 35 mm² Voltage protection level L-N 1.1 kV Max. PV-voltage – V Max. discharge surge current (8/20) 20 kA System configuration TN-S Yes System configuration TN-C No Type / Test class 2 Yes Integrated backup fuse No With remote signalling contact No Short-circuit breaking capacity (Isccr) – kA Voltage protection level N-PE 1.4 kV System configuration IT No System configuration TN No System configuration DC No System configuration TT Yes System configuration other No System configuration TN-C-S No · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2224955